Various Settings ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Page - Fellow Kogyo FOCAS-2000 Instruction Manual

15ppm bilge alarm oil concentration detector
Table of Contents

Advertisement

Page. 17
Setting
6
.
Various settings (Setting)
6-3.
You can change settings according to your operating conditions.
Keep on pressing "Esc" for 2 seconds or longer in the standby state to change settings.
You cannot change settings in the Operation mode.
Setting data and ranges
6-3-1.
Setting data
Warming-up time
Oil alarming point 1
(alarm signal 1/AL1 lamp)
Oil alarming delay 1
(alarm signal 1/AL1 lamp)
Oil alarming point 2
(alarm signal 2/AL2 lamp)
Oil alarming delay 2
alarm signal 2/AL2 lamp)
Alarm suppression
(during warm-up, washing operation, and setting)
Washing timer (automatic washing time)
Washing timer (manual washing time)
During standby
During washing
Exceeding the oil alarming point
RECout
Exceeding the oil concentration of 30
ppm (measuring limit)
During setting
With equipment fault
Setting method
Standby
Clock adjustment menu
Setting menu
Warm-up time setting
screen
Changing a set value
Returning to the setting
item screen
The above setting method in a black box is also applicable to the other setting items. (see the next page for the other setting items.)
Press "Esc" to stop the setting operation halfway. The setting item screen is displayed back.
Setting items
Warming up
Oil Alarm 1
Alarm 1 Delay
Oil Alarm 2
Alarm 2 Delay
Alarm Suppress
Auto Washing Time
Man. Washing Time
Stand by Current
Washing Current
Over Oil Alarm
Over range Current
Maint. Current
Defect Current
The new setting becomes valid after it is saved. Select the screen below and press "Enter" to save it.
Variable range
30 to 300
5 to 15
0 to 5
5 to 15
0 to 600
Alarm output : OFF /
Alarm suppression: ON
30 to 600
10 to 600
0 to 4
0 to 4 or 20 to 24
Density or 20 to 24
20 to 24
0 or 20 to 24
0 or 20 to 24
Keep on pressing "Esc" for two seconds or longer in the standby state.
A clock adjustment item is displayed. Press " ."
Return to standby press "Esc"
A setting menu item is displayed. Press "Enter."
Return to standby press "Esc"
Press "Enter."
This example sets a warm-up time.
The cursor blinks at a digit you can enter a value.
The cursor blinks at a value entry digit ("xx" in the example).
Select a value by using " " or " " and press "Enter." The value is
set and changing ends.
Press " ." The next setting item is displayed on screen.
...(see "Caution" on the next page.)
Value set at
factory
Step
shipment
1
30
1
15
1
0
1
15
10
0
ON
---
(Alarm suppression)
1
60
1
50
1
0
1
4
Densit
1
1
20
1
0
1
0
Units
sec.
ppm
sec.
ppm
sec.
---
sec.
sec.
mA
mA
mA
mA
mA
mA

Advertisement