15ppm bilge alarm oil concentration detector
Table of Contents

Advertisement

Page. 3
General
1
.
Safety precautions
■ 1-3.
● Shut off the power when undertaking construction of the equipment (installation, piping and wiring).
DANGER
Fire, electric shock or injury may be caused due to a short circuit.
● Do not machine, disassemble or modify the product. An accident, fire, electric shock, electronic part mage or burnout may
be caused. If the product has been modified, we cannot take charge of repair.
WARNING
● Do not use the product when it is faulty. An accident such as electric shock and fire may be caused.
Stop the operation at once and repair the product.
● This machine is not provided with a power switch for the primary power supply.
Be sure to install a power switch at the power supply source.
● Do not leave the product in a subzero environment in the status where sample water or fresh water remains in the sample
water detection tube. The sample water detection tube will be broken by freezing, resulting in a failure.
● Never feed water contaminated with oil or impurities directly into the detection tube in the sensor unit. Since this machine
is a precision equipment, a malfunction or impossibility of measurement may be caused by contaminated detection tube.
CAUTION
● Please use the battery properly without making mistakes in terms of orientation of polarity.
Equipment might break down or be heated which leads to ignition.
● Never use the operational log memory card of this oil concentration detector (FOCAS-2000) for the existing oil
concentration detector (FOCAS-1800). If used, its data will be lost. We cannot assure and recover any operational log
data lost by the use in the existing oil concentration detector. By the way, FOCAS-2000 can read the operational log
memory card of FOCAS-1800.

Specifications

2
.
Product Specification
■ 2-1.
Application
Measurement method
Operation method
Response time
Power supply / power consumption
Measurement range
Measurement accuracy
Conditions on samplewater
Fresh water pressure for washing
Material measured and identified
Battery for clock and lifetime
Service temperature・humidity
Bearable vibration
Maximum measurement
angle of inclination
Indications and Outputs
Terminal specification
/oil alarm operating point
Operation recording
function
Piping bore
Cable gland
Water-proof grade
External dimensions ,
weight
Bilge concentration monitor (bilge wastewater)
Optical continuous measurement
Automatic operation using sample water pressure
5sec or less, (comply with MEPC107(49))
AC90 ~ 240 V 50 ~ 60 Hz 20 VA or less
30ppm in full scale
±5ppm or less (at 15ppm)
pressure: 0.03 ~ 0.3MPa
water temperature: +2 ~ +45°C
0.03 ~ 0.6Mpa
light oil 10ppm in 100ppm iron oxide solution
Lithium battery(CR2450) about 2 years (recommended maker : FDK Energy Co Ltd. Japan)
0 ~ 50°C, 5 ~ 90%RH, no dew condensation
2Hz to 13.2Hz,amplitude ±1.0mm, 13.2Hz to 80Hz, acceleration ±0.7G
Within 22.5°in each direction
Indication of oil concentration:displayed in 24 digits 2 lines. alpha-numeral
Power lanp :Green LED lighting , Alarm lamp : Red LED blinks
Alarm1、Alarm2、VALVE Each contact output、REC Analog output
VALVE
Specification A Contact output: 1 circuit, 1B contact (max. 250 VAC 2 A), supply voltage output
(For theree-way valve)
Specification B Contact output: 1 circuit, 1C contact (max. 250 VAC 2 A), supply voltage output
Alarm1 (5~15ppm variable)
Alarm2 (5~15ppm variable)
RECout (4-20mA output)
Power-on and -off, output and release time of respective alarms (record memory: 2 Mbit), conformant to MEPC 107(49)
Inlets of sample water and fresh water, and drain port: Outer diameter of 8 or 10 with copper tube ring joints
4 pcs( 10.5 ~ 14.5)
IP = 54
W = 251mm × H = 283.5 mm × D = 122 mm,
Total weight:approx. 4.8 kg
flow rate: 0.2 ~ 3 L /min
1 circuit for contact output, C contact(Max AC250V 2 A) Delay time: 0 to 5 s
1 circuit for contact output, C contact(Max AC250V 2 A) Delay time: 0 to 600 s
DC4-20mA(0-24mA) line resistance less than 750Ω