Haier FlexFit Pro Series Service Manual page 84

Table of Contents

Advertisement

4.4 Power module error code checking for 1U48LP2VHA
1. Explanation of LED
LED Model
LED 601 (Green)
2. Protection function
Category of protection:
Category
When the voltage, current, temperature,
etc. to meet the shutdown protection
Shutdown protection
Level, drive immediately stop output,
and LED display fault information, and
3. Protection error lists
Hardware/software
Error Code
Protection
1
Software
2
Software
3
Software
4
Hardware
6
Software
7
Software
8
Software
9
Software
10
Software
11
Software
12
Software
13
Software
14
software
15
Software
16
Software
19
Software
20
Software
21
Software
22
Software
23
24
25
27
30
32
Software
34
Software
Appendix A Protection function logic and protection level
Explanation of LED Display
Flashing (on,1s, off,1s) : driver
works normally. Flashing (on,0.25s,
off, 0.25s, flash several times, then
off for 2 seconds ) : power module
failure.
Explanation
upload the error symbol
Error Detail
PIM module overheat
PIM temperature sampling failure
Overcurrent protection when limit frequency
Hardware protection PIM_INT
DC under voltage
DC high voltage
Communication error
Output lack of Phase
Reserved
U phase overcurrent
Compressor is out of step
V phase overcurrent
W phase overcurrent
Compressor startup failure
Phase current sampling failure
AC input under voltage
AC input overvoltage
AC input overcurrent
Input current sampling failure
Preset
Preset
Preset
Preset
Preset
PFC overcurrent of
PFC high voltage
LED Display
LED
Description
Flashes n times,
LED 601
off 2s; (n is the
(GREEN)
error code)
105°C and continued 5s
80
FlexFit Pro
LED Location
Power module
Error Recovery
Needs to keep the
error information 2min,
then error Recovery
Display
Protection Level
Symbol
01H
/
18H
/
02H
PIM_INT
04H
180V
05H
390V
06H
/
07H
/
16H
/
40A
0AH
/
0EH
40A
0CH
40A
0DH
/
0FH
/
09H
155V
11H
280V
12H
35A
13H
/
08H
75A
14H
430V
15H
/