Haier HSU-09LE04 - annexe 1 Operation Manual
Haier HSU-09LE04 - annexe 1 Operation Manual

Haier HSU-09LE04 - annexe 1 Operation Manual

Split type room air conditioner
Hide thumbs Also See for HSU-09LE04 - annexe 1:

Advertisement

SPLIT TYPE ROOM AIR CONDITIONER

OPERATION MANUAL

Please read this operation manual before using the air conditioner.
0010511927
FJT-12L
FJT-18L
FJT-24L
HSU-07LD03
HSU-09LE04
HSU-12LE04
HSU-18LE04
HSU-22LE04

Advertisement

Table of Contents
loading

Summary of Contents for Haier HSU-09LE04 - annexe 1

  • Page 1: Operation Manual

    SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL FJT-12L FJT-18L FJT-24L HSU-07LD03 HSU-09LE04 HSU-12LE04 HSU-18LE04 HSU-22LE04 Please read this operation manual before using the air conditioner. 0010511927...
  • Page 3 Outdoor Minimum: D.B 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07 RN-F or 245IEC57(YZW). 3. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
  • Page 4: Parts And Functions

    (Don't adjust it manually.) Actual inlet grille may vary from the one shown in the manual according to the product purchased For 22k unit, the power plug is on the outdoor unit Outdoor Unit...
  • Page 5: Clock Set

    Clock set 24. HEALTH Used to operate the healthy function When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes. Press to set correct time.
  • Page 6 22. RESET Used to reset the controller back to normal condition. When unit is started for the first time and after replacing batteries in remote controlle clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes. Press to set correct time.
  • Page 7: Operation

    When sudden power failure happens during unit operation in power failure resume mode, the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied,...
  • Page 8 All indicators on indoor unit go out. Vertical flap closed automatically. Hints Remote controller can memorize settings in each operation mode. To run it next time just select the operation mode and it will start with the previous setting. No reelecting is needed.(TIMER ON/OFF needs reelecting)
  • Page 9: Cool And Dry Operation

    On reaching temp. setting, unit will run in mild DRY mode. Hints On cooling only unit, heating mode is not available. Remote controller can memorize each operation status. When starting it next time, just press ON/OFF button and unit will run in previous status.
  • Page 10 Be careful not to catch a cold when cold air blows downward. It is harmful to your health in summer to go frequently in and out of places where temp. difference is above 7 C.
  • Page 11: Timer Operation

    TIMER Operation Set Clock correctly before starting Timer operation You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1)After unit start, select your desired operation mode.
  • Page 12 Follow the same procedures in "Time setting for TIMER ON". (6) Time confirming for TIMER OFF After time setting, press SET button to confirm, "OFF" stops flashing Time displayed: Unit stops at X hour X min. To cancel TIMER mode...
  • Page 13: Health Operation

    The anion generator in the air conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean...
  • Page 14: Emergency Operation

    Removal of the restriction of emergency or test operation: Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated. When the remote controller is manipulated, it gets the system back to the normal operation mode.
  • Page 15 Operation Comfortable SLEEP Before going to bed at night, you can simply press the SLEEP button and unit will bring you a sound sleep in selected mode. ON/OFF TEMP In COOL mode MODE One hour after SLEEP mode starts, temp. will...
  • Page 16: Maintenance

    Cut off power supply before cleaning unit casing with soft cloth. In case of heavy stain, clean it with neutral detergent. squeeze water in the cloth, wipe off the detergent on unit casing completely. Cleaning of remote controller Don't use water to wash unit casing, please use dry cloth.
  • Page 17: Replacement Of Air Purifying Filter

    6.Close the Inlet Grille Close the Grille surely NOTE: Please replace the air Purifying Filter when color of the filter become same levle of sample attached in the indoor unit. Please replace the air Purifying Filter in 3-6 months as standard.
  • Page 18 Avoid time-wasteful operation Never fail to observe the followings Do not sprinkle water over Do not block the inlet or outlet. the unit. Do not pull power plug. Do not use for other purposes. Such as food preservation plant cultivation or animal breeding.
  • Page 19: Troubleshooting

    Performance casing expanding or shrinking because of inspection temperature changes Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells Smells are generated. from the interior air such as the smell of furniture, cigarettes.

Table of Contents