Commands To Add/Remove Rollover (Call Button) Phone Numbers - Select Engineered Systems SG2CL User Programming Manual

Cellular select gate
Hide thumbs Also See for SG2CL:
Table of Contents

Advertisement

Select Engineered Systems - Cellular Select Gate Programming Guide

2.3 Commands to Add/Remove Rollover (Call Button) Phone Numbers

Visitors get attention by pushing the black 'Call' button on the front of the Cellular Select Gate (CSG). This
button will only work if a phone number has already been programmed as 'rollover phone #1' into the
CSG. Two other rollover numbers (#2 and #3) can also be added so that if number #1 is not answered, then
phone #2 will be dialed, and if #2 is not answered, phone #3 will be dialed. The order the CSG dials rollover
phone numbers is set by assigning the dialing sequence number as 1, 2 or 3.
Note – Voicemail Answering and Ringing Time Before Rollover
If the call is answered either by a human or by a call answering service (e.g. voicemail), no further rollover
will occur for that button push. If you wish the dialer to rollover before voicemail answers, set the Ringing
Time to less than the time it takes for the answering service to "kick-in".
Adding and Removing Rollover (Call Button) Phone Numbers
All commands define the existing programming password as "PPPP". Wherever "PPPP" occurs, substitute your own
programming password e.g. the examples use factory default "1234".
Command
Command Text
Name
Add a
*12*PPPP#1S[Phone Number]#
Rollover (Call
1 = Command to Add a Call Button Number
Button) Phone
S= dialing sequence number (1, 2 or 3)
Number
[Phone Number] = 3-15 characters (digits 0-9)
Example: Add a rollover number 3058235410 in dialing sequence location 1:
Text = *12*1234#113058235410#
Remove a
*12*PPPP#1S*#
Rollover (Call
1 = Command to add a rollover number
Button) Phone
S*= remove dialing sequence number (1, 2 or 3)
Number
Example: Remove the rollover number in dialing sequence location 2:
Text = *12*1234#12*#
Set Ringing
*12*PPPP#52[Rollover Time]#
Time Before
52 = Command to set the Ringing Time Before Rollover
Rollover to
[Rollover Time]= Ringing Time Before Rollover (10-99
Next Number
seconds) (Default 20 seconds)
– Applies to
Example: Set Ringing Time Before Rollover to 20 seconds:
all Rollover
Text = *12*1234#5220#
Calls
$
Set Call Time
*12*PPPP#53[Call Time]#
(Time Before
53 = Command to set the Call Time
a connected
[Call Time]= Time Before Call is Terminated (005-999
call dialed
seconds, must be 3 digits) (Default 060 seconds)
from the CSG
Example: Set Call Time to 90 seconds:
is Terminated)
Text = *12*1234#53090#
$
Call Time also affects the time the phone line is allowed to be open when in Intercom Mode.
Page 10 of 30
2019_03_D
Text (SMS) Response
Accepted: "OK"
Not Accepted: Error response (see Sec.
2.10, Fig 8)
Accepted: "OK"
Not Accepted: Error response (see Sec.
2.10, Fig 8)
Accepted: "OK"
Not Accepted: Error response (see Sec.
2.10, Fig 8)
Accepted: "OK"
Not Accepted: Error response (see Sec.
2.10, Fig 8)