ENFORCER Quad-Photobeam Detectors

Selectable 4-channel beam frequency:

The sensor beam frequency can be set at different
levels on-site to avoid interference from other
photobeam sensors nearby. To select between four
different beam frequencies, adjust the beam
channel switch of the transmitter side and receiver
side. See pg. 3, fig. 1 for switch location and table 2
for switch position.
Fig. 9: Receiver Detail
Fig. 10: Included Beam Alignment Template:
Use the included SECO-LARM template to aid in aligning
the transmitter and receiver.
8
Table 2: Channel
Beam Frequency Selection Chart
Freq. channel CH1 CH2 CH3
Switch position
1 2
Important
– The transmitter and receiver
must be programmed to the same channel.
DIP Switch Channel Selector
Beam Alignment Buzzer Switch
Beam Alignment Strength Indicator Switch
Response Time Adjustment
CH4
1 2
1 2
1 2
®