Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 3. Specifications Model Power supply 230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz Air temperature: 15ºC, RH70%, inlet/outlet water temperature: 26ºC/28ºC Heating capacity 1.10 - 3.80 1.30 - 5.10 Power input 0.14 - 0.75 0.17 - 1.06...
Page 5
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Continued: Model Type Refrigerant Charged GWP value Equivalent CO 0.3375 0.4725 Brand GMCC GMCC Model KSK103D53UFZ KSK103D53UFZ Type DC inverter, rotary DC inverter, rotary Quantity Compressor Capacity 3.220 (@60rps) 3.220 (@60rps) Input 0.839 (@60rps)
Page 6
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Model Power supply 230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz Air temperature: 15ºC, RH70%, inlet/outlet water temperature: 26ºC/28ºC Heating capacity 1.60 – 6.70 2.18 - 8.13 Power input 0.21 - 1.34 0.28 - 1.59 5.00 - 7.70...
Page 7
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Continued: Model Type Refrigerant Charged GWP value Equivalent CO 0.6750 0.8775 Brand GMCC GMCC Model KTN150D42UFZ KTN150D42UFZ Type DC inverter, twin-rotary DC inverter, twin-rotary Quantity Compressor Capacity 4.680 (@60rps) 4.680 (@60rps) Input 1.185 (@60rps)
Page 8
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Model Power supply 230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz Air temperature: 15ºC, RH70%, inlet/outlet water temperature: 26ºC/28ºC Heating capacity 2.86 - 10.65 3.49 - 13.00 Power input 0.38 - 2.17 0.47 - 2.64 4.9 - 7.6...
Page 9
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Continued: Model Type Refrigerant Charged 1.58 GWP value Equivalent CO 1.0125 1.2150 Brand GMCC GMCC Model KTN150D42UFZ KTM240D57UMT Type DC inverter, twin-rotary DC inverter, twin-rotary Quantity Compressor Capacity 4.680 (@60rps) 7.715 (@60rps) Input 1.185 (@60rps)
Page 10
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Model Power supply 230V~, 1Ph, 50Hz Air temperature: 15ºC, RH70%, inlet/outlet water temperature: 26ºC/28ºC Heating capacity 3.76 - 15.70 Power input 0.48 - 2.75 5.10 - 7.52 Heating capacity 15.70 Boost mode 5.10...
Page 11
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Continued: Model Type Refrigerant Charged GWP value Equivalent CO 1.3500 Brand GMCC Model KTM240D57UMT Type DC inverter, twin-rotary Quantity Compressor Capacity 7.715 (@60rps) Input 2.085 (@60rps) Current 9.40 (@60rps) Oil type / charged...
Page 12
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Model Power supply 230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz Air temperature: 15ºC, RH70%, inlet/outlet water temperature: 26ºC/28ºC Heating capacity 5.15 - 18.52 5.43 - 21.28 Power input 0.68 - 3.77 0.73 - 4.30 4.91 - 7.53...
Page 13
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Continued: Model Type Refrigerant Charged GWP value Equivalent CO 1.7550 2.0250 Brand GMCC GMCC Model KTF310D43UMT KTQ420D1UMU Type DC inverter, twin-rotary DC inverter, twin-rotary Quantity Compressor Capacity 10.0010 (@60rps) 13.700 (@60rps) Input 2.765 (@60rps)
Page 14
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Model Power supply 230V~, 1Ph, 50Hz Air temperature: 15ºC, RH70%, inlet/outlet water temperature: 26ºC/28ºC Heating capacity 6.34 - 23.68 Power input 0.87 - 4.80 4.90 - 7.60 Heating capacity 23.68 Boost mode 4.90...
Page 15
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Continued: Model Type Refrigerant Charged GWP value Equivalent CO 2.2275 Brand GMCC Model KTQ420D1UMU Type DC inverter, twin-rotary Quantity Compressor Capacity 13.700 (@60rps) Input 3.700 (@60rps) Current 7.02 (@60rps) Oil type / charged...
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 6. Operation range Air ambient temperature range Setting temperature range -15ºC - 43ºC Cooling: 8ºC - 25ºC; Heating: 15ºC - 40ºC 7. Refrigerant system diagram Notes: Hi-pressure switch: When the refrigerant pressure in the system is higher than 4.5MPa, the hi-pressure switch will be triggered and the unit will shut down.
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 8. Accessories Items Shapes Quantity Remarks Installation and For guidance, installation operation manual and operation. For water inlet/outlet Water connectors connection. To protect the unit during Winter cover winter. Rubber gasket To reduce vibration.
Page 22
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 gas leakage and gas accumulation in the area surrounding the unit, it could cause explosions. Please use the specified electrical wires and attached shielded wires to connect the unit’s terminal board. Incorrect connection may cause fire.
Page 23
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 i21 / i25: (Unit: mm) i29 / i32: (Unit: mm) The clearance of the unit (Unit: mm):...
Page 24
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 9.3 Water pipes connection Drainage pipe connection Water connections/fittings on unit: Model i5 / i7 / i9 118mm 350mm 106mm i11 / i14 / i17 123mm 380mm 106mm i21 / i25...
Page 25
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Connection between unit and water pipes...
Page 26
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Typical installation The heat pump is connected to a filtration circuit with a by-pass valve. The by-pass valve only should be half-open (throttled), while all the other valves should be completely open.
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 9.5 Trial running After water system and electrical wires have been connected, the unit should be ready for a trial run. Before starting the trial run, please double-check the following: a.
Page 29
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Output rate Wi-Fi signal Inlet water / Outlet water Alarm for error Temperature or error display Notes: If the unit power is off, there will be no temperature showing on the display, and the unit output rate will be 0%.
Page 30
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 press this to go back to the previous screen. When in query or configuration mode, press and hold this button for 3 to 5 seconds to quit this mode. 10.4 Functions...
Page 31
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Item code Item value Running frequency of compressor (Hz) EEV Open degree (Displayed value/5) Ambient air temperature (ºC) Outlet water temperature (ºC) Discharge temperature of refrigerant (ºC) Suction temperature of refrigerant (ºC) Air side heat-exchanger pipe temperature (ºC)
Page 32
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Code Error or protection Water flow protection Refrigerant system high pressure protection Refrigerant system low pressure protection Over-heating protection of air side heat-exchanger pipe Discharge temperature protection Anti-freeze protection of outlet water...
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Temperature sensor failure of IPM E31 – E36 Reserved Limit frequency according to modular current Limit frequency according to modular voltage Communication failure of fan motor 11. Unit Functions Auto restart function The unit restarts and resumes the set operating conditions in the event of a power supply shutdown without modification of the controller by hand.
Page 34
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 If Ts (set temperature) -1ºC < T (inlet water temperature) < Ts+0.5ºC, the unit will keep running at 35% frequency. If Ts (set temperature) +0.5ºC < T (inlet water temperature) < Ts+1ºC, the unit will keep at 25% frequency.
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 started and runs for 30 seconds, the water flow switch circuit will be activated. If the circuit is broken (no flow), the heat pump will stop running, and P01 will be displayed.
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Wifi function Method 1 Android system: Scan the QR code on an Android system browser. Download the APP and install it. IOS (Apple): Scan the QR code to download the APP and install it.
Page 42
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Register Please ensure that your mobile is already connected to a valid Wi-Fi. Open the APP. Press Register to sign up for the first time.
Page 43
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Type your email address and press Next. Please complete all fields requested, including Email address, Username, Password and Password confirmation, then press Finish to sign-up. After signing up successfully, the display will automatically change to the Log-in screen.
Page 44
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Configuration of APP...
Page 45
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Enter Email address or Username, password and press Sign in button. Press the button Connect heat pump, and the display will be change to next screen.
Page 46
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Follow the instructions on the screen to start operation. After setting up the unit, press Next. On this screen, select your router in your home LAN.
Page 47
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Enter your router’s password, and click Binding and then Next. On this screen, select a name for your heat pump. Press click here to set Wi-Fi.
Page 48
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 For Android systems, the screen will directly skip to the settings menu of your mobile to select HF-LPB130. For IOS systems, you need to manually enter the settings menu of your mobile to select HF-LPB130.
Page 49
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 II. Icons Setting When you press the Setting icon, the display will be change to the setting screen as shown below On this screen: a. The name of the heat pump connected to your mobile APP can be changed.
Page 50
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Mode setting icon This is used to select and switch between the operating modes: Auto, Cooling and Heating. When you press it, the display will enter the mode-selection screen, where you can set cooling mode, heating mode or auto mode.
Page 51
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Function setting icon This is used to select and switch between the operating functions: boost, smart and silent. When you press it, the display will enter the mode-selection screen, where you can set boost mode, smart mode or silent mode.
Page 52
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Fault icon Press Fault to show the history of error codes, as well as current errors or protection codes.
Page 53
Proteam i-Series Inverter Installation and Operation Manual (R32) v.190114 Add heat pump icon Press this to add another heat pump as shown below. Repeat steps mentioned previously to add another unit. Refresh icon Press this to refresh the current set temperature and ambient temperature on the screen.
Need help?
Do you have a question about the Proteam i-Series and is the answer not in the manual?
Questions and answers