Replace the drive unit oil
Only change the oil when the drive unit is warm to the hand; if not, drive the excavator warm.
•
Park the excavator on level ground so that the drain plug (figure below/2) is positioned at the bottom.
•
Place a catch tray with a minimum capacity of 2 L under the drain plug.
•
Remove the drain plug and let the oil drain completely.
Install the drain plug with a new sealing ring on it.
•
Remove the oil filler plug (1).
•
Fill oil as specified in the "Recommended lubricants" section
(page 116). The oil level is the lower edge of the thread.
Capacities:
KX61-3
KX71-3
•
Refit the oil filler plug with a new sealing ring and tighten it.
•
Perform the same service on the second drive unit.
Greasing the pilot valve linkage
•
Pull up the rubber boot on the control lever (3).
•
Lubricate the u-joint (1) below the plate (2) with grease. See
the "Recommended lubricants" section (page 116).
•
Insert the rubber boot in the console.
•
Carry out the service for the second control lever.
Checking the electric cables and connections
•
Check all accessible electric cables, connectors and connections for condition and security.
•
Repair or replace damaged parts.
•
Check the fuse box and fuse holders for oxidation and dirt, clean if necessary.
112
0.35 L
0.60 L
Maintenance