Spellman EPM Series Instruction Manual

Spellman EPM Series Instruction Manual

High voltage power supply

Advertisement

Quick Links

High Voltage Power Supply
SPELLMAN
HIGH VOLTAGE ELECTRONICS
CORPORATION
475 Wireless Blvd.
Hauppauge, New York, 11788
+1(631) 630-3000*FAX: +1(631) 435-1620*
E-mail:
sales@spellmanhv.com
Website: www.spellmanhv.com
EPM/SMS MANUAL
EPM/SMS SERIES
MODEL :
SERIAL# :
DATE :
R
118027-001 Rev G

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EPM Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Spellman EPM Series

  • Page 1 EPM/SMS SERIES High Voltage Power Supply MODEL : SERIAL# : DATE : SPELLMAN HIGH VOLTAGE ELECTRONICS CORPORATION 475 Wireless Blvd. Hauppauge, New York, 11788 +1(631) 630-3000*FAX: +1(631) 435-1620* E-mail: sales@spellmanhv.com Website: www.spellmanhv.com EPM/SMS MANUAL 118027-001 Rev G...
  • Page 2 WICHTIGE SICHERHEITSHINWEISE SICHERHEIT DIESES HOCHSPANNUNGSNETZTEIL ERZEUGT LEBENSGEFÄHRLICHE HOCHSPANNUNG. SEIN SIE SEHR VORSICHTIG BEI DER ARBEIT MIT DIESEM GERÄT. Das Hochspannungsnetzteil muß immer geerdet sein. Berühren Sie die Stecker des Netzteiles nur, wenn das Gerät ausgeschaltet ist und die elektrischen Kapazitäten des Netzteiles und der angeschlossenen Last entladen sind. Die internen Kapazitäten des Hochspannungsnetzteiles benötigen ca.
  • Page 3 PRECAUTIONS IMPORTANTES POUR VOTRE SECURITE CONSIGNES DE SÉCURITÉ ETTE ALIMENTATION GÉNÈRE DES TENSIONS QUI SONT DANGEUREUSES ET PEUVENT ÊTRE FATALES OYEZ EXTRÊMENT VIGILANTS LORSQUE VOUS UTILISEZ CET ÉQUIPEMENT Les alimentations haute tension doivent toujours être mises à la masse. Ne touchez pas les connectiques sans que l’équipement soit éteint et que la capacité à la fois de la charge et de l’alimentation soient déchargées.
  • Page 4 IMPORTANTI PRECAUZIONI DI SICUREZZA SICUREZZA QUESTO ALIMENTATORE GENERA TENSIONI CHE SONO PERICOLOSE E POTREBBERO ESSERE MORTALI. PONI ESTREMA CAUTELA QUANDO OPERI CON QUESO APPARECCHIO. Gli alimentatori ad alta tensione devono sempre essere collegati ad un impianto di terra. Non toccare le connessioni a meno che l’apparecchio sia stato spento e la capacità interna del carico e dell’alimentatore stesso siano scariche.
  • Page 5: Table Of Contents

    Table of Contents PAGE 1. INTRODUCTION Description of the EPM/SMS Series..............1 EPM/SMS Specifications ..................1 Standard Features ....................2 Options .........................2 Interpreting the Model Number ................2 2. INSPECTION & INSTALLATION Initial Inspection ....................3 Mechanical Installation ..................3 Installation Instructions ..................6 3. OPERATING INSTRUCTIONS Operation ......................7 Standard Features ....................8 4.
  • Page 6 7. REPLACEMENT PARTS Replacement Parts ....................19 Correspondence and Ordering Spare Parts ............19 8. FACTORY SERVICE Warranty Repairs ....................20 Factory Service Procedures ..................20 Ordering Options and Modifications ..............20 Shipping Instructions ...................20 APPENDIX Specification Controls (Custom Models Only) LIST OF FIGURES EPM Module Dimensions ..................4 SMS Module Dimensions ..................5 SMS Typical Operating Set Up ................9 EPM Typical Operating Set Up ................9...
  • Page 7: Introduction

    24VAC ±10% or 28Vdc ±10%. (The user should specify • Stability: the input voltage at the time of order). The EPM series operates at 30W continuous and the SMS series operates 0.01% per hour after 1/2 hour warm up. at 60W continuous. Neither series requires forced air •...
  • Page 8: Standard Features

    Consult the capabilities. After the series name is: Spellman’s Sales Department for information on slow start options. (The slow start time will be a function of set The maximum voltage (in KV). point, input voltage and load conditions).
  • Page 9: Inspection & Installation

    Notify the For custom mounting requirements or specific package size requirements consult Spellman’s carrier and Spellman immediately if damage is evident. Do not destroy or remove any of the Sales Department. Spellman has many package packing material used in a damaged shipment.
  • Page 10: Epm Module Dimensions

    Remote Programming: FUNCTION Permits remote adjustment of the output voltage Ground and current via an external voltage source. By +28Vdc adjusting the voltage source from 0V to 10V the desired output may be selected. High Voltage Enable/Inhibit Remote Monitor: Voltage Test Point: 10V±2% = 0 to Rated Output Test points, pins 4 and 5 of the input connector, monitor voltage and current outputs.
  • Page 11: Sms Module Dimensions

    Remote Programming: FUNCTION Permits remote adjustment of the output voltage and Ground current via an external voltage source. By adjusting the +28Vdc voltage source from 0V to 10V the desired output may be selected. High Voltage Enable/Inhibit Remote Monitor: Voltage Test Point: 10V±2% = 0 to Rated Output Test points, pins 4 and 5 of the input connector, monitor voltage and current outputs.
  • Page 12: Installation Instructions

    Dieses Geraet ist zugelassen gemaess 2.3 Installation Instructions EN60950:1993/AM1:1993/AM2:1993 and EN61010- The following are installation instructions for the below 1:1993. Im falle das diesses Geraet in listed models. They are approved in accordance with Informationstechnik-einrichtung eingegaut werden soll, EN60950:1993/AM1:1993/AM2:1993 EN61010- die installation muss gemaess den obengenannten Norn 1:1993.
  • Page 13: Operating Instructions

    Chapter 3 Operating Instructions For initial turn-on, program the voltage and 3.1 Operation current for zero output. Connect the enable/disable signal to disable, open the interlock. WARNING The DC input power may now be connected. THIS EQUIPMENT GENERATES Enable the power supply via the enable/disable DANGEROUS VOLTAGES THAT MAY BE logic signal.
  • Page 14: Standard Features

    (0) to 10 (10) volts equals 0-100% of the via analog isolation amplifiers. Spellman application output. See Figure 3.3 and 3.6 for test point wiring. engineers are available to assist in interface circuitry design.
  • Page 15: Sms Typical Operating Set Up

    Figure 3.1 SMS Typical Operating Set Up Figure 3.2 EPM Typical Operating Set up EPM/SMS MANUAL 118026-001 REV K...
  • Page 16: A Sms Remote Programming Via Voltage Source

    Figure 3.2A SMS Remote Programming Via Voltage Source ____________________________________________________________________________________ Figure 3.2B SMS Remote Programming Via External Resistance EPM/SMS MANUAL 118026-001 REV K...
  • Page 17: Sms Remote Monitoring

    Figure 3.3 SMS Remote Monitoring ____________________________________________________________________________________ Figure 3.4A SMS HV ON/OFF Enable (Low) Control EPM/SMS MANUAL 118026-001 REV K...
  • Page 18: B Sms Hv On/Off Enable (Hi) Control

    Figure 3.4B SMS HV ON/OFF Enable (Hi) Control ____________________________________________________________________________________ Figure 3.5A EPM Remote Programming Via Voltage Source EPM/SMS MANUAL 118026-001 REV K...
  • Page 19: B Epm Remote Programming Via External Resistance

    Figure 3.5B EPM Remote Programming Via External Resistance ____________________________________________________________________________________ Figure 3.6 EPM Remote Monitoring EPM/SMS MANUAL 118026-001 REV K...
  • Page 20: A Epm Hv On/Off Enable (Low) Control

    Figure 3.7A EPM HV ON/OFF Enable (Low) Control ____________________________________________________________________________________ Figure 3.7B EPM HV ON/OFF Enable (Hi) Control EPM/SMS MANUAL 118026-001 REV K...
  • Page 21: Principles Of Operation

    The high voltage transformer is a step-up type. blocks of the EPM/SMS series power supply. For details secondary of the high voltage transformer is connected to on a specific circuit, consult Spellman’s Engineering the high voltage rectifier circuit. The rectifier circuit will Department.
  • Page 22: Options

    Spellman welcomes the opportunity to tailor its units to fit if allowed to clamp. your requirements or to develop new products for your applications.
  • Page 23: Floating Ground Interface Circuit

    Figure 5.1 Floating Ground Interface Circuit EPM/SMS MANUAL 118026-001 REV K...
  • Page 24: Maintenance

    Spellman Customer Service Department. Test equipment, including an oscilloscope, a high impedance voltmeter, WARNING and a high voltage divider such as the Spellman HVD-100 or HVD-200, is needed for performance tests. All test components must be rated for operating voltage.
  • Page 25: Replacement Parts

    Chapter 7 EPLACEMENT ARTS 7.1 Replacement Parts 7.2 Correspondence and Ordering Spare Parts Pellman provides parts and assemblies for its high voltage power supplies but recommends that only Each power supply has an identification label on the rear qualified personnel perform the repair. High voltage of the chassis that bears its model and serial number.
  • Page 26: Factory Service

    The Warranty is void if the unit is worked detailed estimate will be made when the power supply is on by other than Spellman personnel. See the Warranty in received at the Spellman Repair Center. In the event that the rear of this manual for more information.
  • Page 27 To obtain information on Spellman’s product warranty please visit our website at: http://www.spellmanhv.com/en/About/Warranty.aspx...