Omicron Lab TICRO 100 Quick Start Manual page 11

Table of Contents

Advertisement

Connector
OMICRON
Description
Optical output 4 and 5 (ST connector, 820 nm).
Outputs 4 and 5 can be configured in the Web Interface for the following
signals:
- IRIG-B unmodulated
- PPX (adjustable number of pulses, for example, 1 PPS or 1 kHz)
- DCF77 unmodulated
- Trigger (1 pulse at a defined point in time)
- Trigger (PPX sequence starting at the defined point in time)
For information about configuring these outputs, please refer to section
"Output configuration page" of the TICRO 100 User Manual.
RJ45: 10/100Base-TX twisted-pair Ethernet port (RJ45 socket).
FIBER: 100Base-FX optical fiber Ethernet port (ST connector, 820 nm).
The LEDs indicate the link status and data traffic.
TICRO 100 can use only one Ethernet port at a time.
If no Ethernet port is selected in the Web Interface, the RJ45
Ethernet port is the default port if TICRO 100 does not detect an
operating Ethernet network on any of the network ports during the
first power-up or after a factory reset. It is strongly recommended to
set the network port in the Web Interface manually during
commissioning (see section "Network configuration page" in the
TICRO 100 User Manual).
USB port (USB 2.0, type B). Use this interface as an alternative for
connecting a computer to TICRO 100 (instead of accessing TICRO 100 via
Ethernet).
Access via the USB port can be disabled in the security configuration (see
Access Restrictions tab in section "Security configuration page" of the
TICRO 100 User Manual).
When accessing the TICRO 100 Web Interface via the USB port,
you should take care that the computer is not connected to the
Ethernet network TICRO 100 is connected to. The computer must
not be connected to TICRO 100 over the Ethernet network and the
USB port at the same time!
Device description
11