Checking the
bypass nozzles
Checking burning safety
Models with a
burner safety
device
3.
Moisten the area around the nozzle with foam.
4.
Push in the control knob and turn it anti clockwise.
Gas is supplied in this way.
If the foam dissolves or gas escapes, see "If gas
escapes".
1.
Open the locking device for the gas connection.
Check each bypass nozzle individually for leaks.
2.
To do this, hold the opening of the burner nozzle
shut with a finger and carefully lock it using a
special device.
3.
Moisten the area around the bypass nozzle of the
respective burner with foam.
4.
Press in the shaft of the tap or cup and turn it
anti clockwise. Gas is supplied.
If the foam dissolves or gas escapes, see "If gas
escapes".
After converting the appliance to another gas type, the
burning behaviour and the smoke build up for each
hotplate must be checked.
If problems appear, you will need to compare the
nozzle values with the values in the table.
1.
Operate the gas burners.
23