Fitting The Thermal Insulation Jacket - Viessmann Vitocell 300-B Installation Instructions Manual

Table of Contents

Advertisement

500 l capacity
(cont.)

Fitting the thermal insulation jacket

Note
Ensure that no fleece remnants enter the DHW cylin-
der through the cylinder connections.
2 people are required for the following work.
6x
2.
6x
4.
6x
Fig. 9
1. At the back of the cylinder: attach 6 clip fastenings
to the edges of the right and left sections of the
insulation jacket and lay the thermal insulation
jacket around the cylinder body.
Note
Leave the clip fasteners in the first notch.
2. At the front of the cylinder: attach 6 clip fasteners
to the edges of the right and left sections of the
thermal insulation jacket.
6x
1.
3.
3. Push the clip fasteners at the back of the cylinder
as close together as possible.
4. Push the clip fasteners at the front of the cylinder
as close together as possible.
13