Checking The Temperature Sensors - Viessmann EM-S1 Installation And Service Instructions Manual

Solar module extension
Table of Contents

Advertisement

Repairs
(cont.)

Checking the temperature sensors

jF
jF
[{] [{] [{] [{{]
%
&
Fig. 7
100
10
1
0.1
0
20
25
40
Temperature in °C
Fig. 8
Collector temperature sensor
A
NTC 20 k
)
Ω
B
Cylinder temperature sensor
NTC 10 k
)
Ω
1. Disconnect the plug from the relevant temperature
2. Compare the sensor resistance with the curve (see
3. In the event of severe deviation, replace the sen-
B
60
80
100
(sensor type:
&
%
(sensor type:
sensor and check the resistance.
the following diagram).
sor.
A
120
140
Troubleshooting