Divided mowing area with a pond and a
free-standing tree
Docking station:
Location (1) directly next to the house A
No-go area:
Installation around the free-standing tree,
based on a linking section installed at right
angles to the edge.
Pond:
For safety reasons (specified wire
clearance), the perimeter wire (2) is routed
around the pond B.
Wire clearances: (
12.5)
Clearance to the edge: 33 cm
Clearance to adjoining area that can be
travelled on (e.g. footpath) with a stepped
0478 131 9942 C - EN
area height of less than +/- 1 cm: 0 cm
Around the tree: 33 cm
Clearance to the pond: 100 cm
Corridor:
Installation of a corridor (3). Wire
clearance: 27 cm (
12.11)
Guide loops:
Installation of two guide loops (4) for using
the offset drive home function.(
Minimum clearance from the corridor
entrance: 2 m
Note the minimum clearance to corners.
(
12.12)
Programming:
Define the total size of the mowing area,
program two starting points (5) (close to
the docking station and in the contorted
corner near the pond) (
11.15)
Points to note:
Unmown areas, e.g. around the pond must
be mown manually on a regular basis or
cut using a suitable lawn trimmer.
11.14)