Message:
4003 – Hood lifted
Check hood
Then press OK
Possible cause:
– Hood has been lifted
Remedy:
– Check the hood and confirm the
message with OK
Message:
4004 – Internal fault
Press OK to release
Possible cause:
– Error in the programme sequence
– Power failure during automatic
operation
– Robotic mower is located outside the
mowing area
Remedy:
– Confirm message with OK
– Check power supply to the docking
station – the red LED must be
illuminated permanently during
operation; then press the OK
button (
13.1)
– Return the robotic mower to the mowing
area, then press the OK button
Message:
4005 – Internal fault
see message 4004
Message:
4006 – Internal fault
see message 4004
Message:
4008 – Internal fault
see message 4004
170
Message:
4027 – STOP button pressed
Press OK to release
Possible cause:
– STOP button has been pressed
Remedy:
– Confirm message with OK

25. Troubleshooting

Support and help on use
Support and help on use are available
from a STIHL specialist dealer.
Contact options and further information
can be found at https://support.stihl.com or
https://www.stihl.com.
If necessary, contact a specialist
dealer; STIHL recommends STIHL
specialist dealers.
Fault:
The robotic mower operates at the wrong
times.
Possible cause:
– Date and time incorrectly set
– Active times incorrectly set
– Machine has been operated by
unauthorised persons
Remedy:
– Set the time and date (
– Set the active times (
– Set the safety level to "Medium" or
"High" (
11.16)
Fault:
The robotic mower fails to operate during
an active time
Possible cause:
– Battery is charging
– Automatic mowing switched off
– Active time switched off
– Rain detected
– Weekly mowing duration has been
reached, no further mowing operations
required that week
– Message is active
– Control panel not correctly inserted
– Docking station not connected to power
supply
– Outside allowed temperature range
– Power failure
Remedy:
– Allow the battery to finish charging
(
– Switch on automatic mowing (
– Release the active time (
– Set the rain sensor (
– No further action necessary, mowing
operations are automatically distributed
over the week – if necessary, start the
mowing operation with the "Mowing"
command (
– Rectify displayed fault and confirm the
message with OK (
– Insert the control panel (
– Check power supply to the docking
station (
– Allow the robotic mower to warm up or
11.11)
cool down – standard temperature
11.6)
range for operation of the robotic
mower: +5°C to +40°C. Detailed
information is available from your
specialist dealer.