11.1.3 Electrical data

Power supply
Max. power consumption
Enclosure class
Electrical safety class
Control interface (HMI)
Control strategy
Observe the wiring diagram and the separate
Caution
electrical installation and operating instructions,
which are supplied to certified service staff only.

11.1.4 Transport dimensions and weights

Packing box dimensions
Description
Length
AQpure system with
standard UF module
1660
only
AQpure system with
1740
all modules
External CIP unit
840

UF membrane

2000
GAC filter
2000

11.1.5 Feed water requirements

The values in this section define the feed water quality
requirements for the AQpure system. Coarse pollutants bigger
than 300 μm and abrasive particles must be removed from the
water entering the system. The customer is responsible for the
relevant pre-treatment of the water.
Before entering the UF treatment process, the water quality must
comply with the values stated in the table below. Otherwise the
warranty of the system is voided.
If the parameters are above the maximum
Note
recommended values, the performance and capacity
of the system might be affected.
Parameter
Unit
Turbidity
NTU
TSS
mg/L
TOC
mg/L
COD
mg/L
Mn
Oil & grease
mg/L
Particle size
micron
pH continuous
-
pH cleaning
-
46
200-240 V
1-phase, 50/60 Hz
1500 W
IP41
I
PLC-based 7"
touchscreen
Long service
intervals - Parametric
to be very flexible
Weight
[mm]
[kg]
Width
Height
1030
2240
429
1135
2240
612
850
1215
93
355
550
75
500
565
67
Maximum
Desirable
recommended
<50
300
<20
100
<10
40
<20
60
0
<2
<150
300
6-9
2-11
1-12
1-12
11.2 UF membrane
Membrane type
Membrane material
Membrane pore size
pH range
Max. TMP
Max. air scouring flow
Max. backwash pressure
Max. sodium hypochlorite (NaClO)
Recommended transport and storage
temperature

11.3 Activated carbon filter module

Particle size of GAC
Minimum iodine value of GAC
Amount of GAC in filter vessel (min./max.)
Total filter vessel volume

11.3.1 Filter cartridge for cartridge filter

Pore size
Material
Type
Diameter external
Diameter internal
Length
Hollow fibre,
dead-end,
outside-in
PVDF
[μm]
0.03
2-11
[bar]
2.1
3
[m
/h]
12
[bar]
2.5
[mg/l]
2
[°C]
20-35
[mesh]
12-40
950
[l] 90 / 100
[l]
154
[μm]
5
PP
meltblown
114 / 4.5
[mm / inch]
26 / 1