GRUNDFOS INSTRUCTIONS
AQpure
Modular water treatment system
Installation and operating instructions

Advertisement

Table of Contents
loading

Summary of Contents for Grundfos AQpure

  • Page 1 GRUNDFOS INSTRUCTIONS AQpure Modular water treatment system Installation and operating instructions...
  • Page 2: Table Of Contents

    Sections 1-5 give the information necessary to be able to unpack, Power management install and start up the system in a safe way. 6.7.1 AQpure system with solar package module Sections 6-12 give important information about the system, as 6.7.2 AQpure system with UPS...
  • Page 3: General Information

    Cartridge filter 1. General information 8.14.1 Filter cartridge specification 1.1 Documentation package 8.14.2 Preparations 8.14.3 Cartridge filter overview The documentation delivered with the AQpure system comprises: 8.14.4 Maintenance of cartridge filter • Installation and operating instructions for AQpure Repair •...
  • Page 4: Obligations Of The User

    Filtrate is the filtered water that has passed the Filtrate knowledge and documents received during the training at membrane. Grundfos. The flux rate is the filtrate volume flow per m Flux rate • Train the users in performing the user relevant maintenance membrane surface area.
  • Page 5: Abbreviations

    Test sequence to check the integrity Pressure they are adhered to. Grundfos recommends to follow good of the UF membrane fibres with air, Decay Test practice when handling chemicals, and to use personal protective also referred to as integrity test.
  • Page 6: Sodium Bisulfite Solution

    2.2 Working near the AQpure 3.2 Scope of delivery The sound pressure level of the AQpure system is up The system is shipped in several packages: to 90 dbA. Caution •...
  • Page 7: Installation

    Break tank 4.1.1 Installation with AQtap water dispenser Isolating valve The AQpure system can be combined with one or more AQtap Inline strainer water dispensers installed downstream the AQpure system. Suction line The connection of AQpure systems with AQtap dispensers is only Feed pump possible with external tank setup 2.
  • Page 8: Hydraulic Connections

    4.4 Hydraulic connections Q2 Q1 Fig. 3 Hydraulic connections...
  • Page 9: Hydraulic Connection Table

    4.4.1 Hydraulic connection table This table refers to fig.: 3. Hydraulic connections for normal operation: Only systems with To be Pos. Description Fitting Size Type module connected to Backwash connection from activated Double adaptor Female Activated carbon filter Thread 1" carbon filter socket threaded...
  • Page 10: Commissioning

    Net weight: Assembled in India 6.2.1 Intended use The purpose of the Grundfos AQpure water treatment system is DK-8850 Bjerringbro, Denmark to produce potable water by filtering bacteria, viruses and particles from certain types of raw source water. The AQpure Fig.
  • Page 11: Type Key

    6.3.2 Type key Example: AQP-UF-1-C1-PL-UV-D-SP-RM Code Description Type AQpure Technology Ultrafiltration Number of modules 1 module Combination 1 Combination 2 Combination 3 Combination 4 Combination 5 Main combination Combination 6 Combination 7 Combination 8 Combination 9 Combination 10 Combination 11...
  • Page 12: Aqpure Modules

    6.4 AQpure modules The core component of the AQpure system is the standard UF module for ultrafiltration. The standard UF module is included in all possible configurations of an AQpure system. Additionally an AQpure system can comprise a number of modules and accessories. The quality of the raw water intake determines, which modules are required for the water purification process.
  • Page 13 Pos. Module Description The standard UF module is included in all possible configurations of an AQpure system. The most basic configuration for an AQpure system comprises only this module. It comprises all components relevant for the ultrafiltration (UF) process and the basic self-cleaning tasks. If no solar package module is used, the system includes an Uninterruptible Power Supply (UPS) to put the system into a safe state in case of power failure.
  • Page 14 6.5.1 External tank setup options. The external tank is not supplied by Grundfos but always sourced locally by the operating company to avoid high shipping costs. However the pressure sensor used to determine the water level in the external tank, is supplied by Grundfos. The level sensing module includes only the pressure sensor.
  • Page 15: Piping And Instrumentation Diagram (Pid)

    6.5 Piping and Instrumentation Diagram (PID) The following PID shows an AQpure system that comprises all modules. Furthermore, the two possible setups (ETS1 and ETS2) for the installation of an external clean water tank are shown. Hydraulic connection External CIP connection...
  • Page 16: External Tank Setup Options

    6.5.1 External tank setup options This section refers to fig.: 6. There are two different setups for the external tank installation. Setup 1 with external tank (ETS1) In setup 1, the water flows from the internal tank (46) through the overflow pipe to the external tank (ETS1) based on gravity or on an external pump that is controlled by the operating company.
  • Page 17: Location Of Pid Components

    6.5.2 Location of PID components AQpure standard UF module Fig. 7 AQpure standard UF module Pos. Description Pos. Description Standard UF module: Sight glass Flow sensor Sight glass Flow sensor Manual valve Pressure sensor Air release valve Pressure sensor Manual valve...
  • Page 18 AQpure standard UF module with self-cleaning prefilter module Fig. 8 AQpure standard UF module with self-cleaning prefilter module Pos. Description Pos. Description Standard UF module: Air release valve Flow sensor Manual valve Flow sensor Internal tank backwash Pressure sensor Manual valve...
  • Page 19 AQpure optional modules (without solar package module) Fig. 9 AQpure optional modules (without solar package and remote management module) Pos. Description Pos. Description Air scouring module: External CIP unit: Compressor Chemical tank Transparent hose Heater Non-return valve Non-return valve Non-return valve...
  • Page 20: Process Description

    – Tapping UV light Manual control is protected with a special password Alarm handling and must only be used by Grundfos service Caution If an alarm is activated while the task is active, the following specialists. sequence is activated: 6.6.2 Production runtime...
  • Page 21: Filling Of The External Tank

    If a level sensing module is available, the external tank (ETS1 gravity or an external pump that is controlled by the operating or ETS2) must not be empty. Otherwise the internal tank (46) company and not by the AQpure system. Once the Production must not be empty.
  • Page 22: Backwash Of Uf Membrane

    6.6.9 Backwash of UF membrane Adaptive activation volume Once a BW has been activated, the counter for the water that has This section refers to fig.: 6-8. run through the membrane and the counter for the idle time are A backwash (BW) is performed to remove fouling on the surface reset.
  • Page 23: Backwash Of Gac Filter

    11. Filling of chemical tank (50) with clean water (2nd time). This task controls the system in case of power failure. 12. Outside flush along UF membrane (13), (1st time). AQpure system with solar package module 13. Emptying of chemical tank (50) to chemical waste tank (CWT), Low power control is activated in case of a power failure.
  • Page 24: Integrity Test

    If an alarm is activated while the task is active, the following supplied to certified service staff only. sequence is activated: The AQpure system is either equipped with the solar package 1. Feed pump (GP1) and backwash pump (GP2) are stopped. module or with an UPS (Uninterruptible Power Supply).
  • Page 25: Aqpure System With Ups

    UPS1 is available and production on external power is disabled. In case of external power runtime, power failure can happen due Fig. 11 AQpure system with UPS to the following reasons: • External power is not available and batteries have been discharged twice in a day.
  • Page 26: Operation

    HMI application. Wait at least 2 minutes before operating the system Note from the HMI. See fig. 12, pos. P1. 7.3 Operational modes The AQpure water treatment system has two operational modes: • Automatic mode • Semi-automatic mode These two operational modes are mutually exclusive. The system can either be in automatic mode or in semi-automatic mode.
  • Page 27: User Hmi

    10. Taking the system out of operation. application, a startup screen with the Grundfos logo is displayed. After startup the user screen is displayed. Depending on the installed modules, different internal cleaning sequences are automatically performed before the system stops The user screen comprises several elements: and switches into semi-automatic mode.
  • Page 28: Warning And Troubleshooting

    HMI shows the status as shown in fig. 15. the HMI: If the Grundfos Eye is in warning state and there is no warning 1. Press the particular module button, which is highlighted in red indication on any of the four modules, press the [Service] button colour.
  • Page 29: Warnings And Alarms

    7.5.1 List of warnings Type Indication System behaviour alarms. Shortened instructions on these maintenance tasks are presented at the HMI after pressing the picture of the The Grundfos Eye in the Warning System keeps running respective component. See also section: 7.4 User HMI.
  • Page 30 Type Code Description Remedy Alarms Pump (GP1) - Current: overload Call certified service staff Alarms Pump (GP1) - Over temperature: motor temperature Call certified service staff Alarms Pump (GP1) - Over temperature: temperature, control electronics Call certified service staff Alarms Pump (GP1) - Over temperature: thermo relay 2 in motor Call certified service staff Alarms...
  • Page 31 Type Code Description Remedy Warnings Pump (GP5) - Time for service is exceed Call certified service staff Warnings Pump (GP5) - Capacity too low Call certified service staff Warnings Pump (GP5) - Soon time for service Call certified service staff Warnings Pump (GP5) - Gas in pump head deaerating problem Call certified service staff...
  • Page 32: Manual Valves

    PID. See fig.: 6-9. 7.7 Grundfos Remote Management (GRM) An AQpure system can include a remote management module. If this module is included, the system is able to send and receive data from Grundfos Remote Management (GRM). The GRM module features the following functions: •...
  • Page 33: Maintenance

    Check the feed water supply. Check the UV intensity value displayed at the UV controller. The UV controller can be found at the lower back side of the AQpure control cabinet. Actions should be taken according to the displayed value: UV disinfection •...
  • Page 34: Advanced Maintenance Schedule (Only Certified Service Staff)

    Details can be found in the separate HMI manual, The following tasks must only be performed by which is supplied to certified service staff only. certified service staff. This staff must have received proper training from Grundfos before any work on the system. Interval Component Task Inspection of general installation conditions.
  • Page 35: Lubricants

    8.5 Lubricants 8.7 Service kits For drinking water applications, food-safe grease must be used. 8.7.1 Standard UF module Danger of damage to the UF membrane! Product Description Qty. Fig. Pos. Ingress of oil or grease will damage the UF number Caution membrane irreversibly.
  • Page 36: Activated Carbon Filter Module

    8.7.6 Activated carbon filter module 8.10 Strainers This section refers to fig.: 6-9. Product Description Qty. Fig. Pos. The strainer (11) is only present in systems without self-cleaning number prefilter module to ensure, that no particles larger than 300 µm Kit, cartridge filter maintenance enter the UF membrane.
  • Page 37: Maintenance Of Strainer

    Warning Danger from running system! Danger from running system! Make sure, that the Grundfos Eye has stopped Make sure, that the Grundfos Eye has stopped rotating before starting any work on the system rotating before starting any work on the system...
  • Page 38: Self-Cleaning Prefilter

    8.11.4 Maintenance of prefilter Read section: 8.11.1 Safety instructions. This section is only relevant, if the AQpure system is The following steps refer to fig.: 19-20. Note equipped with a self-cleaning prefilter module. See 1. Unless the system is already stopped due to an active alarm, fig.
  • Page 39 Cleaning 21. When all parts are cleaned, dip the housing parts (5.8), (5.10) and all parts of (5.11) into a bucket filled with the selected cleaning agent. – All parts must be immersed completely in the sodium hypochlorite solution. – Let the parts soak for about 15 minutes. 22.
  • Page 40: Chemical Tank

    8.12 Chemical tank 8.12.4 Refilling the chemical tank Read section: 8.12.1 Safety instructions. This section is only relevant, if the AQpure system is Note equipped with a chlorination module. See fig. 5, pos. 21.1 21.2 The chlorination module includes a sensor in the chemical tank.
  • Page 41: Uv Disinfection Module

    8.13 UV disinfection module 8.13.3 Overview UV system This section is only relevant, if the AQpure system is 45.15 Note equipped with an UV disinfection module. See fig. 5, 45.1 pos. 3. Some components of the UV disinfection module can get dirty or worn, and need cleaning or replacement after a certain time.
  • Page 42: Cleaning Or Replacing The Quartz Sleeve And The Sensor

    8.13.5 Cleaning or replacing the quartz sleeve and the sensor Warning Dismantling Risk of burns! The following steps refer to fig.: 9. Depending on when the power supply was switched 1. If the lamp is not yet removed, remove the lamp as described off, the UV lamp might still be very hot.
  • Page 43: Switching On/Off The Uv Lamp

    1. To switch off the UV lamp, press the power button (45.20) at agents. the UV controller on the back of the AQpure control cabinet 15. Clean the quartz sleeve with a soft cloth or replace it by a new for 2 seconds.
  • Page 44: Cartridge Filter

    8.14 Cartridge filter 8.14.4 Maintenance of cartridge filter 1. Unless the system is already stopped due to an active alarm, This section is only relevant, if the AQpure system is stop the system by pressing the [Stop] button on the HMI. Note equipped with an activated carbon filter module.
  • Page 45: Repair

    10.1.1 Storage with installed membrane Weight empty (excluding consumables): 1. Stop the system by pressing the [Stop] button on the HMI. • AQpure system with standard UF module – If the system cannot be stopped, e.g. due to ongoing [kg]...
  • Page 46: Electrical Data

    11.1.5 Feed water requirements The values in this section define the feed water quality requirements for the AQpure system. Coarse pollutants bigger than 300 μm and abrasive particles must be removed from the water entering the system. The customer is responsible for the relevant pre-treatment of the water.
  • Page 47: Dimensional Drawings

    For systems without this module 1 m is sufficient. ** Minimum space required for installation and maintenance of UF membrane. Fig. 28 Dimensions of AQpure system, connections and space requirement. Dimensions in mm Pos. Description Raw water inlet Backwash outlet...
  • Page 48: Disposing Of The System

    Clean water outlet (UV module) 1. Use the public or private waste collection service. External tank inlet water (UV module) 2. If this is not possible, contact the nearest Grundfos company or service workshop. 12.1 Disposing of chemicals Dispose of chemicals according to the local environmental...
  • Page 49 7 Jalan Peguam U1/25 Telefax: +66-2-725 8998 L6H 6C9 Glenmarie Industrial Park Turkey Phone: +1-905 829 9533 40150 Shah Alam GRUNDFOS POMPA San. ve Tic. Ltd. Sti. Telefax: +1-905 829 9512 Selangor Gebze Organize Sanayi Bölgesi Phone: +60-3-5569 2922 China Ihsan dede Caddesi, Telefax: +60-3-5569 2866 GRUNDFOS Pumps (Shanghai) Co.
  • Page 50 98868426 1217 ECM: 1218908 www.grundfos.com...