9. Repair
The system must only be repaired by certified service staff
according to the separate service instructions, which are supplied
to certified service staff only.
10. Taking the system out of operation
To stop the system only for a few hours (e.g. for maintenance),
use the [Stop] button on the HMI. No further action is required in
this case.
For long-term storage observe, that the UF membrane requires
special treatment and conditions. See section:
For storage times and storage conditions different to the ones
described below, contact certified service staff.
Observe the separate supplier documents for the
Caution
components. All supplier documents are part of the
documentation package delivered with the system.
Observe the permissible ambient conditions. See section:
11.1.2 Ambient
conditions.
10.1 Short-term decommissioning up to 4 days
10.1.1 Storage with installed membrane
1. Stop the system by pressing the [Stop] button on the HMI.
– If the system cannot be stopped, e.g. due to ongoing
cleaning tasks, wait until these tasks are completed and
stop the system again.
2. Press the [Service] button to enter the service menu.
3. Press the [Sleep] button. See section:
10.2 Long-term decommissioning for more than 4
days
10.2.1 Storage of an operable system up to 7 days
1. Operate the system for 45-60 minutes per day during storage
to protect the equipment from bacterial fouling.
10.3 Restarting the system
10.3.1 Restarting the system (users)
If the system was decommissioned according to sections
10.1.1 Storage with installed membrane
operable system up to 7
days, press the [Start] button. The
system starts production in automatic mode again.
Otherwise only certified service staff must restart the system.
3.1
Storage.
7.4.2 Sleep
function.
or
10.2.1 Storage of an
11. Technical data
The values stated in the technical data must be
Caution
adhered to.
For detailed data of the system components see the
separate supplier documents. All supplier documents
Caution
are part of the documentation package delivered with
the system.
11.1 AQpure system
11.1.1 General data
Water production
Max. production runtime per day
Max. water inlet pressure of system*
Permissible water inlet pressure of UV
disinfection module (min./max.)
Max. operating pressure
Permissible water inlet temperature (min./
max.)
Weight empty (excluding consumables):
• AQpure system with standard UF module
only
•
AQpure system with all modules
Weight filled (including consumables):
• AQpure system with standard UF module
only
•
AQpure system with all modules
•
Sound pressure level
* For minimum water inlet pressure, see separate manual of the
feed pump (GP1).
11.1.2 Ambient conditions
Permissible ambient temperatures (min./max.)
Transport*
Storage*
Operation
Max. relative humidity (non-condensing)
Max. altitude above sea level
* System must be drained. Observe special requirements of the
UF membrane. See section:
Direct sunlight can cause damage.
Exposition to direct sunlight can cause changes in
Caution
colour as well as material deformations and cracks.
Do not expose the system to direct sunlight!
Freezing and boiling liquids can cause damage.
Observe the freezing and boiling points of the used
Caution
liquids. The freezing and boiling point of a liquid
varies depending on the pressure.
Because of the embrittlement of plastics at low
temperatures, the transport must not be done if the
Caution
temperature falls below the specified value for
transport, otherwise plastic parts can be damaged.
3
[m
/h]
0.5 - 2
[h]
22
1.5 bar
3
at 1 m
/h
[bar]
0.1 / 3.0
[bar]
3
[°C]
+5 / +40
[kg]
400
[kg]
615
[kg]
750
[kg]
1165
[dbA]
90
[°C]
-5 / +50
[°C]
-5 / +50
[°C]
+1 / +45
[%]
95
[m]
2000
3. Storage and
handling.
45