7.5 Warnings and alarms

A supervision function monitors the system and detects failures.
The failures are categorised into warnings and alarms. See also
section:
7.4.3 Grundfos
Eye.
Type
Indication
The Grundfos Eye in the
Warning
display turns yellow
The Grundfos Eye in the
Alarm
display turns red
The supervision function is always active when the system is in
automatic mode. When the system is in semi-automatic mode,
the supervision function is only active while manual control is
disabled. In manual control, the supervision only covers the
alarms 105, 106, 107, 108, because they are the most important
alarms for the protection of the UF membrane.

7.5.1 List of warnings and alarms

Type
Code
Description
Alarms
100
Sensor signal is missing from pressure sensor BP1
Alarms
101
Sensor signal is missing from pressure sensor BP3
Alarms
102
Sensor signal is missing from pressure sensor BP4
Alarms
103
Flow signal is missing from flow sensor BF1 during production
Alarms
104
Flow signal is missing from flow sensor BF2 while BW pump active
Alarms
105
Pressure on inlet of UF membrane is too high
Alarms
106
Pressure on outlet of UF membrane is too high
Alarms
107
TMP (inlet to outlet) for UF membrane is too high
Alarms
108
TMP (outlet to inlet) for UF membrane is too high
Alarms
109
Water temperature is too low
Alarms
110
Water temperature is too high
Alarms
111
Sensor signal is missing from pressure sensor BP7
Alarms
112
System requires external CIP
Alarms
113
Internal tank alarm limit without overflow
Alarms
114
Sensor signal is missing from pressure sensor BP2
Alarms
115
Pressure on inlet of prefilter (5) is too high
Alarms
116
Internal tank alarm limit with overflow
Alarms
117
POF for prefilter (5) is above alarm limit
Alarms
118
Prefilter (5) backwash timeout
Alarms
119
Time between prefilter (5) backwash activations is too short
Alarms
120
System reboot failure
Alarms
121
Chemical tank (21) is empty
Alarms
122
Sensor signal is missing from pressure sensor BP5
Alarms
123
Sensor signal is missing from pressure sensor BP6
Alarms
124
Pressure on inlet of GAC filter (39) is too high
Alarms
126
POF for cartridge filter (42) is above alarm limit
Alarms
127
UV light intensity failure
Alarms
128
Pump (GP5) - Main network communication fault
Alarms
129
Pump (GP5) - Diaphragm break - dosing pump
Alarms
130
Pump (GP5) - Cable breakdown on analogue
Alarms
131
Pump (GP5) - Blocked motor/pump
Alarms
132
Pump (GP5) - Empty tank (dry running)
Alarms
133
Pump (GP5) - External box communication fault
Alarms
134
Pump (GP5) - Over pressure
Alarms
135
Pump (GP5) - Mean pressure too low (under pressure)
Alarms
136
Pump (GP1) - Current: overcurrent
Alarms
137
Pump (GP1) - Current: blocked motor/pump
The failure codes of active warnings and alarms are displayed
after pressing the [Service] button at the HMI.
Some failures can be fixed by the user by performing the
respective maintenance task. See section:
System behaviour
and
are presented at the HMI after pressing the picture of the
System keeps running
respective component. See also section:
All other failures may only be fixed by certified service staff.
System stops and
Before calling the certified service staff, note down the active
waits for
failure codes displayed in the service menu.
acknowledgement
signal from the user or
the certified service
staff before it starts
again
In addition to warnings caused by failures, the system shows
warnings caused by the scheduled maintenance date. See
section:
alarms. Shortened instructions on these maintenance tasks
Warnings are automatically reset by the system once
the cause is remedied.
Alarms can be reset using the [Reset] button at the
HMI.
Note
If the same alarm occurs and is reset 3 times in a
row, it is no longer possible for the user to reset it.
Certified service staff must be called in this case to
reset the alarm.
8.1.1 Scheduled maintenance
Remedy
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
See section:
Call certified service staff
Call certified service staff
Call certified service staff
See section:
Call certified service staff
Call certified service staff
Call certified service staff
See section:
See section:
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
See section:
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
Call certified service staff
7.5.1 List of warnings