JCM Technologies ROLL868 DMR Quick Start Manual page 2

Advertisement

1248060 / 1.5
Fit the rear of the box to the wall using the raw plugs and screws supplied. Pass the cables through the bottom of the equipment.
Proceed with the starting up of the equipment.
STARTING UP
1. Connect the motor and the power supply.
Connect the motor as shown in the figure above: U (open), V (close), W (common).
Connect the equipment to the 230Vac power supply as shown in the figure above. The red pilot light is activated every 5
seconds indicating the correct power supply to the equipment.
2. Set the switch selector to the desired operating option.
Selector
Position ON (default option)
1
Dead man operating: the control panel operates in
dead man mode for open and close, provided it
is operated from inside the coverage area, previously
adjusted.
3. Programming the dead man transmitters.
Press the programming button PROG for 1 sec: the programming pilot light will come on and the equipment will emit an
acoustic signal. Press any channel of the transmitter, and wait to hear a 0,5 seconds acoustic signal.
Configuration of the transmitter programming into the receiver
Pressing any channel of the transmitter, the relays will be activated by: 1rst channel Open and 2nd channel Close, and
3rd channel Open, 4th channel Close
Note: This control panel only works with dead man transmitters.
Every time a transmitter is programmed, the equipment will issue an acoustic signal for 0.5 sec.
After 10 seconds without programming or by pressing the programming button, the equipment will exit programming mode,
issuing two 1 sec. acoustic signals. If, on programming a transmitter, the equipment memory is full, it will issue seven 0.5
sec. acoustic signals and exit programming.
4. Set transmitters distance activation.
The unit is supplied with the activation distance set at the minimum.
Turn the potentiometer clockwise (to + position) to increase the activation distance
of the transmitters.
Turn the potentiometer to – position to decrease the activation distance of the transmitters.
It is the responsibility of the installer that the selected distance allows the user to have direct view of the door as it is in
motion.
It is recommended to mark this distance with the door closed, and then to verify that the door can be opened and closed
from both sides of it.
If the dead man transmitter is not situated in the activation zone, the LED blinks and three beeps will be heard. In this case
it is necessary to increase the activation distance.
1. « the person operating the door must have a direct view of the doorway, must be near the
door (5 meters maximum) during movement of the door and should not find itself in a
dangerous position »
Any adjustment of the radio range out of these recommendations, undertakes the installer in
terms of responsibility for injury or damage.
2. « Releasing of the pressure maintained control device should stop the door movement before
it scrolls 5cml » . This implies a maximum speed of the door of 12.5 cm / s.
ROLL868 DMR / ROLL868 DMR-P
WARNING: In accordance with the EN 13241-1 and EN 12453-1
standard concerning pressure maintained control devices:
Position OFF
Semi-automatic operating: The control panel operates in
semi-automatic mode for open (maximum manoeuvre 2
minutes),
without
restriction
transmitter and receiver, and in dead man mode for close
(provided it is operated from inside the coverage area).
on distance between
Led R1
ON
-
+
2