  • Page 1 Pioneering for You Wilo-Star-Z NOVA cs Návod k montáži a obsluze en Installation and operating instructions ru Инструкция по монтажу и эксплуатации fr Notice de montage et de mise en service lv Uzstādīšanas un ekspluatācijas instrukcija es Instrucciones de instalación y funcionamiento it Istruzioni di montaggio, uso e manutenzione lt Montavimo ir naudojimo instrukcija el Οδηγίες εγκατάστασης και λειτουργίας...
  • Page 2: Table Of Contents

    Page 6  Type key Page 4 Connecting  Page 8  Electrical connection Page 9  Safety Page 2  Principle of operation Page 6  Installation Page 7  Faults Page 12 Installation and operating instructions Wilo-Star-Z NOVA...
  • Page 3: Safety

    Important safety information is indicated as fol- lows: Danger: Indicates a danger to life due to electrical current. Warning: Indicates a possible danger to life or injury. Caution: Indicates possible risks to the pump or other items. Note: Highlights tips and information. WILO SE 04/2015...
  • Page 4 • The pump is protected against drips in accordance with protection class IP 42. Pro- tect the pump against water spray. Do not immerse in water or other fluids. Installation and operating instructions Wilo-Star-Z NOVA...
  • Page 5: Connections

    C = with check valves and ready for connection with plug clock timer 3.2 Connections Star-Z NOVA Screwed connection: 15 (Rp ½") Star-Z NOVA A and Star-Z NOVA C Screwed connection: 15 (Rp ½") and check valves WILO SE 04/2015...
  • Page 6 + 40 °C temperature Max. permitted total hardness in secondary hot 20 °dH water circulation systems See name plate or Wilo catalogue for further information. 3.4 Scope of delivery 1 Pump 2 Thermal insulation shell 3 Sealing rings 4 Wilo-Connector...
  • Page 7: Principle Of Operation

    This circulator is suitable for drinking water only. 4.2 Functions Valves The Star-Z NOVA A and Star-Z NOVA C versions are equipped with a non-return valve (1) on the pressure side and with a stop valve (2) on the suc- tion side.
  • Page 8: Installation

    Caution: Dirt can cause the pump to fail. Flush the pipe system before installation. Note: In the case of the Star-Z NOVA A and Star-Z NOVA C versions, the stop valve and non-return valve are pre-installed. In the case of the Star-Z NOVA version, these valves have to be installed additionally.
  • Page 9 Caution: Do not damage the housing seal. Replace damaged seals. 4. Turn the motor head so that the Wilo-Con- nector points downwards. Caution: If the position is wrong, water can penetrate and destroy the pump. 5. Tighten the union nut again.
  • Page 10 Before establishing the connection, make sure that the connecting cable is dead. Establish the electrical connection as follows: PE N Fig. 1 Fig. 2 Fig. 3 Fig. 4 Installation and operating instructions Wilo-Star-Z NOVA...
  • Page 11 Installation Open the WILO- Connector as follows: Fig. 5 5.3 Filling and bleeding 1. Fill the system. 2. The pump rotor space bleeds automatically after a short time in operation. This may cause noises. If necessary, switch off and on repeat- edly to accelerate the bleeding.
  • Page 12 This is normal for this situation. Faultless operation can only be guaranteed when the pump is operated in fluid.  Replacing the motor head Page 8. Maintenance/faults Order the service motor from a specialist retailer. Installation and operating instructions Wilo-Star-Z NOVA...
  • Page 13: Faults

    Time switching function Check the plug clock has switched off auto- timer setting. matically (Star-Z NOVA C version only). Motor is blocked, e.g. by Have the pump removed deposits from the water by a qualified technician ...
  • Page 15 EZ IZJAVA O SUKLADNOSTI WILO SE vakuuttaa, että tässä vakuutuksessa kuvatut tuotteet ovat seuraavien eurooppalaisten direktiivien määräysten sekä niihin WILO SE izjavljuje da su proizvodi navedeni u ovoj izjavi u skladu sa sovellettavien kansallisten lakiasetusten mukaisia: VOMHGHüLP SULKYDüHQLP HXURSVNLP GLUHNWLYDPD L QDFLRQDOQLP ]DNRQLPD Smjernica o niskom naponu 2006/95/EZ ;...
  • Page 16 '(./$5$&-$ =*2'12 &, :( :,/2 6( R ZLDGF]D H SURGXNW\ Z\PLHQLRQH Z QLQLHMV]HM GHNODUDFML V WILO SE erklærer at produktene nevnt i denne erklæringen er i samsvar ]JRGQH ] SRVWDQRZLHQLDPL QDVW SXM F\FK G\UHNW\Z HXURSHMVNLFK L med følgende europeiske direktiver og nasjonale lover: WUDQVSRQXM F\PL MH SU]HSLVDPL SUDZD NUDMRZHJR EG–Lavspenningsdirektiv 2006/95/EG ;...
  • Page 17 » -DE. 24. .01946, 26.12.2014 WILO « « », 25.12.2019 III. : WILO SE ( », 123592, ", 220035, TOO «WILO Central Asia», « " , . 20 , 67, 050002, . +7 495 781 06 90, 1101, / 005...
  • Page 18 WILO Norge AS Australia 2ILFLQD &RPHUFLDO :,/2 ,EžULFD 6$ Jakarta Timur, 13950 0975 Oslo WILO Australia Pty Limited (GLILFLR 6LPRQD $SWR   $OFDO– GH +HQDUHV T +62 21 7247676 T +47 22 804570 Murrarrie, Queensland, 6LERQH\ /D +DEDQD &XED...
  • Page 19 WILO SE Nortkirchenstraße 100 D-44263 Dortmund Germany T +49(0)231 4102-0 F +49(0)231 4102-7363 wilo@wilo.com Pioneering for You www.wilo.com...

This manual is also suitable for:

Star-z nova aStar-z nova c