Download Print this page
Wilo Star RS Series Installation And Operating Instructions Manual

Wilo Star RS Series Installation And Operating Instructions Manual

Advertisement

Available languages

Available languages

Quick Links

Wilo-Star RS, RSD, ST, RSG, AC
D
Einbau- und Betriebsanleitung
GB
Installation and operating instructions
F
Notice de montage et de mise en service
NL
Montage- en bedieningsvoorschrift
I
Istruzioni di montaggio, uso e manutenzione
E
Instrucciones de instalación y funcionamiento
S
Installations- och skötselinstruktioner
FIN Huolto- ja käyttöohje
H
Beépítési és üzemeltetési utasítás
PL
Instrukcja montażu i obsługi
CZ
Návod k montáži a obsluze
SK
Návod na montáž a obsluhu
RO
Instrucfliuni de montaj øi expolatare
GR
Οδηγίες εγκατάστασης και λειτουργίας
RUS Инструкция по монтажу и експлуатации
LT
Montavimo ir naudojimo instrukcija
LV
Uzstādīšanas un ekspluatācijas instrukcija
UK
Інструкція по монтажу та експлуатації
TR
Montaj ve kullanma kılavuzu

Advertisement

loading
Need help?

Need help?

Do you have a question about the Star RS Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wilo Star RS Series

  • Page 1 Wilo-Star RS, RSD, ST, RSG, AC Einbau- und Betriebsanleitung Návod k montáži a obsluze Installation and operating instructions Návod na montáž a obsluhu Notice de montage et de mise en service Instrucfliuni de montaj øi expolatare Montage- en bedieningsvoorschrift Οδηγίες εγκατάστασης και λειτουργίας...
  • Page 6 Einbau- und Betriebsanleitung Installation and operating instructions Notice de montage et de mise en service Montage- en bedieningsvoorschrift Istruzioni di montaggio, uso e manutenzione Instrucciones de instalación y funcionamiento Installations- och skötselinstruktioner FIN Huolto- ja käyttöohje Beépítési és üzemeltetési utasítás Instrukcja montażu i obsługi Návod k montáži a obsluze Návod na montáž...
  • Page 7: General Information

    ENGLISH – Industrial, closed circulating 1 General Information systems. These Operating Instructions explain Specific details: the functions and operation of the – Type ST: for thermal solar systems pump when installed and ready for – Type RSG: for geothermal systems use.
  • Page 8 – For use of other kinds of fluids con- Dangers from non-observance of sult WILO first. safety rules Non-observance of safety reference 2 Safety may cause personal injury or damage These instructions contains basic to the pump or installation.
  • Page 9 ENGLISH – Failure of important pump or unit instructions. Under no circumstances functions, should the limit values given in the – Causing personal injury due to data sheet be exceeded. electrical or mechanical causes. 3 Transport/Interim Safety rules for the operator storage Local regulations for the prevention of pump...
  • Page 10 ENGLISH Speed setting (Fig. 8) Accessories The speed of the pump can be adju- Accessories must be ordered separa- sted with a 3-position rotary button. In tely. position 3 the speed is approx. – Inserts for the pipe connection of 40...50 % of the maximum speed with the screwed-pipe pump.
  • Page 11 ENGLISH – Pump to be mounted with the shaft – To guarantee protection against in the horizontal plane in such a dripping water and the strain relief way that it is not stressed by the of the PG screwed joint, a connec- pipework.
  • Page 12: Operation

    ENGLISH – Protect all electrical parts against 6 Operation the leaking water. System filling and venting – Switch-on pump. The pump may need venting e.g. if the It is possible that the ATTENTION! heating and pump are working but the pump blocks with the heating element remains cold.
  • Page 13: Problems, Causes And Remedies

    – Check speed setting, if necessary switch to a lower speed. If the fault cannot be rectified, contact your nearest WILO Customer Service. 9 Spare parts All rating plate data must be stated when ordering spare parts. Subject to technical alterations!
  • Page 15 If the above mentioned series are technically modified without our approval, this declaration shall no longer be applicable. Si les gammes mentionnées ci-dessus sont modifiées sans notre approbation, cette déclaration perdra sa validité. Dortmund, 07.11.2008 Erwin Prieß WILO SE Quality Manager Nortkirchenstraße 100 44263 Dortmund...
  • Page 16 Bu cihazın teslim edildi i ekliyle a a ıdaki EN 61000-6-1 standartlara uygun oldu unu teyid ederiz: Elektromanyetik Uyumluluk 2004/108/EG EN 61000-6-2, 2004/108/EG Alçak gerilim direktifi 2006/95/EG EN 61000-6-3, EG–2006/95/EG EN 61000-6-4, Kısmen kullanılan standartlar: EN 60335-2-51. Erwin Prieß WILO SE Quality Manager Nortkirchenstraße 100 44263 Dortmund Germany...
  • Page 17 T +7 727 2785961 wilo@wilo.dk T +40 21 3170164 1230 Wien in.pak@wilo.kz Taiwan wilo@wilo.ro Estonia T +43 507 507-0 WILO-EMU Taiwan Co. Ltd. Korea office@wilo.at WILO Eesti OÜ Russia 110 Taipeh WILO Pumps Ltd. 12618 Tallinn WILO Rus ooo T +886 227 391655...
  • Page 18 WILO SE Nortkirchenstraße 100 44263 Dortmund Germany T 0231 4102-0 F 0231 4102-7363 wilo@wilo.com www.wilo.de Wilo-Vertriebsbüros in Deutschland G1 Nord G3 Sachsen/Thüringen G5 Südwest G7 West WILO SE WILO SE WILO SE WILO SE Vertriebsbüro Hamburg Vertriebsbüro Dresden Vertriebsbüro Stuttgart Vertriebsbüro Düsseldorf...