Enter Network - Ebyte E104-BT10 User Manual

Tlsr8269f512 uart smd sig mesh module
Hide thumbs Also See for E104-BT10:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd
E104-BT10 User Manual

5.2 Enter network

E104-BT10-G test board and E104-BT10-N are respectively plugged into the computer USB interface (PC needs to
install USB serial drive, see the data compression package), open the serial debugging assistant to select the baud rate
115200bps, 8 data bits, no parity, 1 stop bit, select hexadecimal transmission. The E104-BT10-G terminal edits and sends
the "Device Access" command 02 C0 09. When E104-BT10-N enters the network successfully, the indicator light is
constant. E104-BT10-G receives 0B 40 09EAFD CDBAFEAD 0007 03, where EAFDCDBAFEAD indicates successful
network access equipment. The MAC address 0007 indicates the device's main address (see 2.3 for the format
description). The device is successfully connected to the network.
hengdu Ebyte Electronic Technology Co., Ltd
Copyright ©2012–2019,C
4-22