Sig Message - Ebyte E104-BT10 User Manual

Tlsr8269f512 uart smd sig mesh module
Hide thumbs Also See for E104-BT10:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd
18. To obtain software version number
Operation
Request
Respond
For
Request:02 C0 16
example
Respond:04 40 16 10 00
Notes:
1、Suitable for E104-BT10-G and E104-BT10-N
2、software version number is an unique value
19.To obtain main address of current device
Operation code
Request
Respond
For
Request:02 C0 0B
example
Respond:05 40 0B 01 0004
Notes:
1、Suitable for E104-BT10-G and E104-BT10-N
2、return unicast address of E104-BT10-N device in current network

4.3.2 SIG Message

E104-BT10 supports SIG generic model and Lighting HSL model control ( refer to
Model for details about SIG message).SIG message follows format below:
Command(1 byte) Target address (2 byte) Sig mesh message
Command(1 byte) Target address (2 byte) Original address ( 2
For example:1、Generic onoff control:
hengdu Ebyte Electronic Technology Co., Ltd
Copyright ©2012–2019,C
code
0x16
0x16
0x0B
0x0B
Return main address of current E104-BT10-N device
Transmitting
0xC1
Main address of target
device
0x41
Main address of target
device
Control device with main address 0004, outputting high
level without latency
Request
09
Respond
08
Control device with main address 0004, outputting low
Parameter
/
software version number
Parameter
/
Request
Receiving
byte)
Main address of
original device
C1
00 04 82 02
01
00 00 00
41
00 04 00 01 82 04
01
E104-BT10 User Manual
Mesh Profile and
Mesh
Sig mesh
message
Respond
4-20

Advertisement

Table of Contents
loading