A
80°C / 176°F
60°C / 140°F
50°C / 122°F
45°C / 113°F
40°C / 104°F
0°C / 32°F
-20°C
-4°F
-40°C / -40°F
Fig. 43: Ambient temperature - process temperature, version with temperature adapter
A
Ambient temperature
B
Process temperature (depending on the seal material)
1
Aluminium housing
2
Plastic housing
3
Stainless steel housing, precision casting
4
Stainless steel housing, electropolished
Vibration resistance
Ʋ Rod probe
Shock resistance
Ʋ Rod probe
Electromechanical data - version IP 66/IP 67
Cable gland
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, stranded wire
Ʋ Stranded wire with end sleeve
Display and adjustment module
Display element
Measured value indication
Ʋ Number of digits
Ʋ Size of digits
Adjustment elements
Ʋ 4 keys
Ʋ Switch
70
50°C
80°C
100°C
122°F
176°F
212°F
1 g with 5 ... 200 Hz according EN 60068-2-6 (vibration
at resonance) with rod length 50 cm (19.69 in)
25 g, 6 ms according to EN 60068-2-27 (mechanical
shock) with rod length 50 cm (19.69 in)
M20 x 1.5 or ½ NPT
0.2 ... 2.5 mm² (AWG 24 ... 14)
0.2 ... 1.5 mm² (AWG 24 ... 16)
Display with backlight
5
W x H = 7 x 13 mm
[OK], [->], [+], [ESC]
Bluetooth On/Off
SITRANS LG260 - Operating Instructions
1
2
3
4
150°C
200°C
302°F
392°F
B
PBD-51041059