SUN2000-(30KTL-A, 33KTL, 33KTL-E001, 40KTL)
User Manual
Figure 5-8 Stripping the SUN2000-33KTL/SUN2000-33KTL-E001 AC output cable (including
the ground cable)
Figure 5-9 Stripping the SUN2000-30KTL-A or SUN2000-40KTL AC output cable (excluding
the ground cable)
Figure 5-10 Stripping the SUN2000-30KTL-A or SUN2000-40KTL AC output cable (including
the ground cable)
Step 3 Insert the exposed core wires into the crimp area of the OT terminal and crimp them using
hydraulic pliers.
Step 4 Wrap the wire crimp area with heat shrink tubing or PVC insulation tape.
Step 5 Remove the locking cap from the AC OUTPUT waterproof cable connector at the inverter
bottom and remove the plug from the locking cap.
Issue 10 (2019-06-30)
If heat shrink tubing is used, put it through the power cable and then crimp the OT terminal.
Copyright © Huawei Technologies Co., Ltd.
5 Electrical Connections
46