Troubleshooting
Fault messages
(cont.)
Fault number
System characteristics
on the display
F.581
Control mode without room
influence
F.582
Control mode without room
influence
F.666
Preheating of second DHW
cylinder and solar transfer
pump not working
F.667
Preheating of second DHW
cylinder and solar transfer
pump not working
F.668
Preheating of second DHW
cylinder and solar transfer
pump not working
F.669
Preheating of second DHW
cylinder and solar transfer
pump not working
F.670
No solar central heating
backup
F.671
No solar central heating
backup
F.672
Thermostat function for solar
control and solar transfer
pump not working
F.673
Thermostat function for solar
control and solar transfer
pump not working
F.682
Burner in a fault state
F.683
Burner in a fault state
F.684
Burner in a fault state
96
Cause
Lead break, room temper-
ature sensor, heating cir-
cuit 3
Short circuit, room tem-
perature sensor, heating
circuit 3
Lead break, temperature
sensor, DHW preheating
TS3
Short circuit, temperature
sensor, DHW preheating
TS3
Lead break, temperature
sensor, DHW reheating
TS4
Short circuit, temperature
sensor, DHW reheating
TS4
Lead break, buffer tem-
perature sensor TS3
Short circuit, buffer tem-
perature sensor TS3
Lead break, temperature
sensor, thermostat func-
tion TS3
Short circuit, temperature
sensor, thermostat func-
tion TS3
Air mass flow rate sensor
not installed
Air mass flow rate sensor
faulty
Back draught safety de-
vice faulty
Measures
Check external room temperature
sensor for heating circuit or room
temperature sensor for remote
control unit.
Check external room temperature
sensor for heating circuit or room
temperature sensor for remote
control unit.
Check temperature sensor TS3.
Check temperature sensor TS3.
Check temperature sensor TS4.
Check temperature sensor TS4.
Check temperature sensor TS3.
Check temperature sensor TS3.
Check temperature sensor TS3.
Check temperature sensor TS3.
Install the correct fan.
Reset device.
Replace fan.
Reset device.
Check the back draught safety de-
vice and replace if necessary.
Reset device.