Viessmann Vitodens 200-W B2HE Installation And Service Instructions Manual page 62

Wall mounted gas condensing boiler
Hide thumbs Also See for Vitodens 200-W B2HE:
Table of Contents

Advertisement

System configuration (parameters)
Boiler
(cont.)
522.3 "Interval until the next service"
Setting
596.0 "Maximum heating output"
Setting
597.0 "Limit, max. heating output for DHW heating"
Setting
1100.2 "Set speed of the primary circuit pump in heating mode"
Setting
1411.0 "Clear maintenance messages"
Setting
No
Yes
1503.0 "Minimum heating output"
Setting
62
Explanations
Interval until the next service
0
No interval selected
1
3 months
2
6 months
3
12 months
4
18 months
5
24 months
Explanations
A limit can be set on the maximum heating output for
heating mode.
100
Heating output in the delivered condition 100 %
0 to 100
Adjustable from 0 to 100 %
Explanations
A limit can be set on the maximum heating output for
DHW heating.
100
Heating output in the delivered condition 100 %
0 to 100
Adjustable from 0 to 100 %
Explanations
Set speed of internal circulation pump
In heating mode
With external demand
With demand in conjunction with a low loss header
...
Delivered condition specified by settings specific to
the appliance
20 to 100
Set speed adjustable from 20 to 100 %
Explanations
Clear maintenance messages once maintenance has
been performed.
0
Maintenance messages are active (if present).
1
Clear maintenance messages once.
Explanations
A limit can be set on the minimum heating output for
heating mode.
...
Delivered condition specified by settings specific to
the appliance
5 to 100
Adjustable from 5 to 100 %

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 200-w seriesVitodens 200-w b2keVitodens 200-wB2heB2ke

Table of Contents