Diagnosis and service checks
Checking outputs (actuator test)
Display
Heating circuit pump 2
speed
Heating circuit pump 3
speed
Mixer, heating circuit 2
Mixer, heating circuit 3
DHW group (domestic hot water)
Primary circuit pump,
set speed
3-way valve target posi-
tion
Cylinder loading pump
DHW circulation pump
Transfer pump hygiene
function
Circulation pump for cyl-
inder heating
Solar group
Solar circuit pump, set
speed
Transfer pump hygiene
function
Solar circulation pump
Solar 3-way valve, tar-
get position
76
(cont.)
Explanation
Set value
Speed, heating circuit pump, heating circuit 2 with mixer in %
Set value
Speed, heating circuit pump, heating circuit 3 with mixer in %
Open
Output for "Mixer open" enabled (mixer extension kit)
Stop
Current position is maintained
Close
Output for "Mixer close" enabled
Open
Output for "Mixer open" enabled (mixer extension kit)
Stop
Current position is maintained
Close
Output for "Mixer close" enabled
Set value
Internal circulation pump in %
Heating
Diverter valve set to heating mode
Middle
Diverter valve in central position (filling/draining)
DHW
Diverter valve set to DHW heating
On
Off
On
Off
On
Off
On
Off
Set value
Speed, solar circuit pump in %
On
Off
On
Off
Open
Close
Stop