7.0
Tube Cut Dimensions
When replacing/repairing separable connections with Rynglok
fittings the following dimensions should be used for factoring
tube cut length.
7.1
Female Arcseal Fitting
Tube cut dimension, as shown in Figure 15, shall use dimensions
per Table 6 for proper fitting installation.
Figure 15
Female ArcSeal tube cut dimensions
Table 6
Part No.
"A" +.030 in.
R81101T03
0.463
R81101T04
0.496
R81101T05
0.513
R81101T06
0.528
R81101T08
0.596
7.2
Female Flareless Fitting
Tube cut dimension, as shown in Figure 16, shall use dimensions
per Table 7 for proper installation.
Figure 16
Female flareless tube cut dimensions
Table 7
Part No.
"A" +.030 in.
R82101T03
0.602
R82101T04
0.616
R82101T05
0.695
R82101T06
0.726
R82101T08
0.837
Part No.
"A" +.030 in.
R81101T10
.682
R81101T12
.754
R81101T16
.837
R81101T20
.883
R81101T24
1.023
Part No.
"A" +.030 in.
R82101T10
.979
R82101T12
1.004
R82101T16
1.135
R82101T20
1.165
R82101T24
1.395
Rynglok Fitting System Installation Guide
7.3
Female Flared Fitting
Tube cut dimension, as shown in Figure 17 , shall use dimensions
per Table 8 for proper installation.
Figure 17
Female flared tube cut dimensions
Table 8
Part No.
"A" +.030 in.
R83101T03
0.662
R83101T04
0.701
R83101T05
0.748
R83101T06
0.779
R83101T08
0.920
EATON Aerospace Group TF100-67A March 2013
Part No.
"A" +.030 in.
R83101T10
1.045
R83101T12
1.085
R83101T16
1.214
R83101T20
1.298
R83101T24
1.477