INSTALLATION
STEP 1
CHECK EQUIPMENT
AND JOB SITE
INSPECT EQUIPMENT
File claim with shipping company,
prior to installation, if shipment is damaged or incomplete.
STEP 2
INFINITY CONTROL
TM
LOCATION AND WIRING
CONSIDERATIONS
ELECTRICAL
SHOCK HAZARD
Failure to follow this warning could result in personal injury
or possible equipment damage.
Disconnect Power before routing control wiring.
All wiring
must
comply
with national,
local,
and state codes.
INFINITY
CONTROL
TM
LOCATION
The Infinity
Control
TM
is the command
center *br the Infinity
System.
It should be located
where
it is easily accessible
and visible
to the adult homeowner
or
end user.
For accurate
temperature
measurement,
the following
guidelines
should
be followed:
The Infinity
Control
TM
should
be mounted:
Approximately
5 feet (1.5 meters)
fi'om the floor.
Close to or in a frequently
used room,
preferably
on an inside
partitioning
wall.
On a section
of wall without
pipes
or duct work.
The Infinity
Control
TM
should NOT
be mounted:
(?lose to a window,
on an outside
wall, or next to a door leading
to the outside.
Exposed
to direct light or heat from
a lamp,
sun, fireplace,
or
other temperature-radiating
objects
which
could
cause
a false
reading.
(?lose to or in direct airflow
fi'om supply registers.
In areas
with poor air circulation,
such as behind
a door or in
an alcove.
REMOTE
SENSOR
OPTION
A remote
room
sensor
can be
used with the Infinity
Control
TM
to take the place of the internal
temperature
sensor.
This allows the control
to be mounted
in areas
with
less
than
optimal
airflow
(such
as near
an exterior
door,
window
or in a closet).
The remote
sensor is wired to the terminal
block
connectors
labeled
S1 and $2. The Infinity
Control
TM
will
automatically
detect
the remote
sensor
and
ignore
its
internal
sensor.
It is also important
to note the humidity
sensor
cannot be
remotely
located,
so do not locate the Infinity
Control
TM
in an area
where
humidity
sensing
may not be accurate.
NOTE:
S1 & $2 connection
on UI back-plate
is now used for the
Remote
Room
Sensor,
NOT
for OAT
Sensor
hookup
(S1 & $2
was previously
used for OAT).
WIRING
CONSIDERATIONS
Ordinary
thermostat
wire
is
recommended.
Use 22 AWG
or larger
for normal
wiring
applica-
tions.
Continuous
wire lengths
over 100 ft. should use 20 AWG or
larger.
NOTI=:
ABCD
bus wiring
only requires
a four-wire
connection;
however,
it is good practice
to run thermostat
cable having
more
than four wires
in the event of a damaged
or broken
wire
during
the installation.
Each device in the Infinity
System
has a four-pin
connector
labeled
ABCD.
It is recommended
that the following
color code be used
when
wiring
each device:
A
Green
Data A
B
Yellow
Data B
C
White
24VAC
(Corn)
D
Red
24VAC
(Hot)
It is not mandatory
that the above
color
code be used,
but each
ABCD
connector
in the system
MUST
be wired
consistently.
MOUNTING
INFINITY
CONTROL
TM
There
are two options
fbr mounting
the Infinity
Control
TM
to the wall. First,
familiarize
yourself
with all plastic
assembly
pieces
shown
in Figs. 2 through
9. The User
Interface
will
snap together
with
either
the Recess
Mount
or the Surfi_ce Mount
backplate.
RECESS
MOUNT
This
provides
the thinnest
mounting
con-
figuration
(See
Fig.
3). The backplate
containing
the recessed
terminal
block
can be mounted
directly
to the wall by cutting
a
hole 1 1/,,"wide by 2 1/8" high. Mark location
and cut hole in wall.
NOTI=:
Always
ensure
the Infinity
ControW '_ location
is accept-
able before
cutting
any holes in wall.
SURFACE
MOI_E',_T
This provides
surface
mounting
configu-
ration,
which
allows
use of a small
hole
in the wall. A surface
mount
backplate
is supplied
(See
Fig.
4). Attach
backplate
as
shown
in figure 7, and the assembly
will mount directly
to the wall
requiring
only
a small
hole
in the
wall
allowing
a tour
wire
connection
to pass through.
NOTI=:
Once
Infinity
ControW '_ is secured
to wall
with
the
backplate
assembly
(snapped
together),
care must be taken not to
bend or break the interlocking
tabs when removing.
Gently remove
Infinity
Control
by rocking
up/down
until interlocking
tabs release.
DECORATIVE
BACKPLATE
Supplied,
is a thin, decorative
backplate
(see Fig. 5), to hide any marks/screw
holes left fi'om the
previous
thermostat.
This decorative
backplate
(or beauty ring) can
be used
in either
the
recess
or surface
mount
installation
by
snapping
it onto
the back
of the recessed
mount
backplate
or
surface
mount backplate
before
securing
to the wall. See Fig. 8 and
9 for a larger
decorative
backplate
(5.75"
wide
X 6" tall), which
can be ordered
separately.
Fig. 2--Infinity
Control
TM
STEP 3
INSTALLING INFINITY CONTROL
TM
A03185
ELECTRICAL
SHOCK
HAZARD
Failure
to follow
this warning
could
result in personal
injury
or death.
Before
installing
Infinity
Control
TM,
turn
off all power
to
equipment.
There
may
be more
than one power
source
to
disconnect.
i. Turn off all power
to equipment.
2. If an existing
thermostat
is being
replaced:
a. Remove
existing
themmstat
from wall.
b. Disconnect
wires
from existing
themmstat.