2.
Clean the area around the filter mounting area.
3.
Place a drain pan under the filter and remove
the filter
(Figure
1. Hydraulic filter
4.
Lubricate the new filter gasket and fill the filter
with hydraulic fluid.
5.
Ensure that the filter mounting area is clean.
6.
Screw the filter on until the gasket contacts the
mounting plate, then tighten the filter one–half
turn.
7.
Start the traction unit engine and operate the
hydraulic controls to purge air from the system.
8.
Shut off the engine and check the fluid level and
for any leaks.
Adjusting the Impeller Belt
Service Interval: After the first 20 hours
Before each use or daily
Make sure that the belt is properly tensioned to
ensure proper operation of the machine and prevent
unnecessary wear.
1.
Loosen the bolts and nuts securing the drive
shield to the impeller housing
remove the shield.
11).
Figure 11
(Figure
12) and
g027366
1. Drive shield
Note:
The drive shaft does not have to be
disconnected to adjust the belt.
2.
On back side of the frame, loosen the bolt
securing the belt tensioner to the frame
12).
3.
Remove the bolt and nut securing the tensioner
guide to the drive mount to release the belt
tension
(Figure
1. Tensioner guide
2. Bolt and nut
19
Figure 12
13).
Figure 13
3. Bolt (back of frame)
g027367
(Figure
g027368