Download Print this page

General Specifications - GE GuardSwitch 341-BT Series Installation Manual

Safety interlock switch

Advertisement

CE Compliance Information
These switches are TUV certified for CE applications only when used with the INT
Safety Monitor Relays. See Risk Category 3 and Category 4 wiring diagrams above.
European Directives
Machinery Directive (89/392/EEC)
EMC Directive (89/336/EEC)
Low Voltage Directive (73/23/EEC)
Specific European Standards
EN60204-1 Safety of electrical equipment of
industrial machines
EN292 Part 1, 2 Safety of Machinery, basic
Declaration of Conformity
terminology, technical principles
available upon request.
EN954-1 Risk Assessment Category 3 or 4 depending
on wiring method, see diagrams
EN55081-2 Electromagnetic Emissions
EN50082-2 Electromagnetic Immunity
EN1088 Interlocking Devices
EN947-5-3 Control Circuit Devices
EN50178 Safety of Electrical Equipment
IEC 664-1 Insulation requirements
IEC 68, part 2-1, 2-2, 2-3, 2-8, 2-14, 2-27, 2-30
Wiring Diagram for Category 4
Inputs shown with safety gate/guard in closed position. Two Series 300-B GuardSwitches™ with one INT relay are required for each safety gate.
When first applying the INT Safety Monitor Relay, the inputs must be cycled to check for proper operation before the output contacts close. To cycle the inputs, the guard must be
opened and then closed. This start-up test is sufficient; however, we recommend that the proper operation of the switches and relay be checked at least every 24 hours.
( – )
INT-03-230: 230V AC
INT-03-120: 120V AC
INT-03-024: 24V DC
( + )
R e q u i r e d F a s t o r
S l o w - A c t i n g F u s e :
( 2 5 0 V , 5 x 2 0 m m F )
I N T - 0 3 - 2 3 0 : 4 0 m A
I N T - 0 3 - 1 2 0 : 8 0 m A
L1
I N T - 0 3 - 0 2 4 : 1 / 4 A
Safety Monitor Relay
INT-03
A
Required Fast or
Slow-Acting
Fuses: 4A (250V,
5x20 mm F
230 VAC
LOADS
60 VDC
GE Security Industrial
RESET
W
H
T
L2 1
2
X1 X2 Y1 Y2
+
N.O.
N.C.
*Or other DPST GuardSwitch
OUTPUTS
(See the 300-BT Series
SAFE
AUX.
B
C
D
E
F
G
installation instructions)
120 VAC
30 VDC
TM
GuardSwitch
Series 300

General Specifications

Enclosure
Temperature Range
Environmental
NEMA Rating
Protection Class
Response Time
Individual circuits
Life Cycles
Lead Types/O.D.
UL/CSA/TUV
File E 122942
B
R
B
W
B
R
L
E
L
H
L
E
D
U
T
D
K
K
*300-BLT-
*300-BLT-
Note – The LED on the BLT model
will be ON when the guard is open
Fuses: 1A (250V)
®
Kynar
, Polyvinylidene Fluoride
14°F to 150°F (-10°C to 65°C)
Hermetically Sealed Contact Switch
Encapsulated in Polyurethane
1, 2, 4, 4X, 5, 12, 12K, 13
IP 67
1 msec
The two circuits do not switch simultaneously, and depend
on the speed of the guard closure. Based on closure speed
of 1' per second and a gap of 1/8", a delay less than
50 msec is typical.
100,000 Under Full Load;
Up to 200,000,000 Under Dry Circuit
18/4 SJTOW (K)/0.34" (0.86cm)
22/4 PVC Jacketed (J)/0.19" (0.48cm)
22/6 PVC Jacketed (J)/0.21" (0.53cm)
All Models
LR89176
B
L
U

Advertisement

loading

This manual is also suitable for:

Guardswitch 300 seriesGuardswitch 343-bt seriesGuardswitch 341-bt-06jGuardswitch 341-bt-12jGuardswitch 341-bt-kGuardswitch 341-bt-12k ... Show all