Safety interlock switch

Advertisement

Quick Links

Description
The 371-BT Series DPST safety interlock switch is designed for use with safety
monitored relays or monitored circuits. To achieve the optimum Series 300 defeat
resistant feature of the 371-BT, both the switch circuit (Circuit 1) and the tamper
circuit (Circuit 2) must be connected.
Notes:
1. Environmental: Pollution Degree II
2. Correct use of this control device is an essential part of proper machine cycle
control.
3. Failure to follow ALL instructions could lead to serious bodily injury or death.
4. Maintenance to be done by qualified personnel only
5. The connecting cables between the INT devices and the switches must be located
in an IP 23 type enclosure (minmum).
6. The mounting for the switch and the actuator magnet must be accomplished per
this specification.
7. Non-removable hardware must be used for installation.
8. The housing of the 300-BT must be connected to the PE (Primary Earth) ground
circuit via a lock washer on the mounting screw. The PE ground symbol must be
placed adjacent to the screw.
To verify switch operation with an ohmmeter:
Set range at 20 mega ohms (switches with triac output, set ohm range at 20 kilo
ohms). For a normally open switch, the meter will read a high impedance with the
actuator away. It will read very high to infinity range (triac switches will read high
kilo ohm to infinity range) with the actuator within sense range. You will see the
opposite reading for a normally closed switch.
Dimensions
5.75''
14.61cm
0.24''
5.27''
13.39cm
0.61cm
0.83''
2.11cm
0.42''
1.07cm
5.75''
14.61cm
0.24''
5.26''
0.61cm
13.36cm
0.64''
1.63cm
2.03''
5.16cm
0.64''
1.63cm
2.33''
1.10''
2.79cm
5.92cm
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
1.51''
3.84cm
0.22''
0.56cm
dia.
1.49''
3.78cm
1.12''
2.84cm
0.28''
0.71cm
GuardSwitch
Safety Interlock Switch
371-BT
371-BT
Installation
Use non-removable screws, bolts, or nuts to mount the switch and actuator. Do not
over-torque mounting hardware.
1. Position the switch and actuator so the labels are reading in the same direction.
(See Figure 1.)
2. Mount the switch on the stationary frame of the machine and mount the actuator
on the moveable guard, door or gate. Keep the switch and actuator within the
listed sense range. (See Ordering Information.)
See Figure 2 or recommended mounting configurations.
3. Mounting on a ferrous material will effect the sense range a minimum of 50%.
However, a 1/4" non-ferrous spacer positioned under the actuator and/or switch
should restore most of the lost sense range.
4. For best protection against operator defeat, mount with non-removable screws,
bolts or nuts (see Accessories).
5. Caution! When not used with a GE INT safety relay, particular care must be taken to
determine the actual load of the switch circuit. High voltage transients from coils,
motors, contactors, and solenoids must be considered. Transient protection, such
as back-to-back zener diodes (TransZorb
such loads to ensure that maximum ratings of the switch are not exceeded. Not
recommended to be used with tungsten filament loads because of high current
inrush surges. Line capacitance and load capacitance must be considered.
Excessive line capacitance can be caused by cable lengths over 50' when using a
maximum 48 VAC. A resistor can be added in series to limit the inrush current (at
least 48 Ohms for 24V applications). The resistor can be added in series just before
the load. The voltage drop and the power rating of the resistor must be considered.
2
Voltage drop = I•R; Watts = I
R (I = maximum continuous current of the load).
Series 300
®
) or an RC network, is recommended for
continued

Advertisement

loading

Summary of Contents for GE GuardSwitch 371-BT Serires

  • Page 1 (see Accessories). 0.22'' 2.11cm 0.42'' 0.56cm 1.07cm 5. Caution! When not used with a GE INT safety relay, particular care must be taken to dia. 5.75'' 1.49'' determine the actual load of the switch circuit. High voltage transients from coils, 14.61cm 3.78cm...
  • Page 2 6. When mounting the switch on an ungrounded machine, ground the switch housing CIR. 1 by connecting your ground lead to one of the switch mounting screws. Figure 1 BLUE CIR. 2 Actuator sensing face Switch sensing face *Circuits shown with magnet actuator away from switch. conduit S1 Normally open reed switch, closed when actuator is within 0.6"...
  • Page 3 CE Compliance Information General Specifications These switches are TUV certified for CE applications only when used with the INT Enclosure UL Explosion Proof, Die Cast Anodized Aluminum Safety Monitor Relays. See Risk Category 3 and Category 4 wiring diagrams above. UL Enclosure Classified for Use in Hazerdous Locations: Class I, Group B, C, D Class II, Group E, F, G...
  • Page 4 Proximity of ferrous materials usually reduces sense range — typically by 50%. The shape and type of material cause a wide diversity of effects. Testing is required to determine actual sense range for specific applications. GE Security Industrial Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com...