  • Page 1 GRUNDFOS INSTRUCTIONS SB, SBA Installation and operating instructions...
  • Page 2: Table Of Contents

    Read this document before you install the These installation and operating instructions product. Installation and operation must describe Grundfos SB, SBA and SB HF. comply with local regulations and accepted Sections 1-5 give the information necessary to be codes of good practice.
  • Page 3: Notes

    If any visible parts have been damaged, contact 1.2 Notes the transport company. The symbols and notes below may appear in Grundfos installation and operating instructions, 2.2 Scope of delivery safety instructions and service instructions. The box contains the following items: •...
  • Page 4 3.1.1 Maximum installation depth SB and SBA pump with a float switch and side inlet Maximum installation depth Product SB HF Min. 3.1.2 Highest tapping point for SBA pumps 10 cm/ 4 inch Install SBA pumps so that the height between the pump and the highest tapping point does not exceed these values: SBA 3-35: 13 m.
  • Page 5: Mechanical Installation

    3.1.4 Vertical placement of SB HF pump 3.2 Mechanical installation Tank installation of SB HF 3.2.1 Lifting the product Place the pump on the bottom of the tank. The pump Lift the pump by the lifting handle. Never lift the must not run dry.
  • Page 6: Pump Position

    3.3 Pump position 3.4 Connecting the outlet hose or pipe 3.3.1 Pump position of SB and SBA External pipe thread Product Use the pump in the vertical position as shown in fig. [inch] G 3/4 or 1 G 3/4 or 1 0 °...
  • Page 7: Electrical Connection

    3.6.2 Connecting to external controller accidentally switched on. - The pump must be earthed. SB pumps must be connected to an external controller. We recommend a Grundfos Pressure DANGER Manager: net.grundfos.com/qr/i/97506325 Electric shock Death or serious personal injury SBA pumps have an integrated control unit.
  • Page 8: Starting Up The Product

    4. Starting up the product 4.1 SBA starting and stopping conditions When water is consumed in the water supply system, WARNING the pump starts when the starting conditions are fulfilled. This happens for example when a tap is Flammable material opened which makes the pressure in the system Death or serious personal injury drop.
  • Page 9: Product Introduction

    SB pump must be connected to an external controller, see section 3.6.2 Connecting to external Grundfos SB, SBA and SB HF pumps are designed controller. for pumping clean water. The pumps are especially suitable for rainwater applications and small private 6.3 SB HF pumps...
  • Page 10: Identification

    Insulation Class F IP68 Clean the strainer every fall with a brush and a water jet when needed. In normal operation, the pump Made in Italy by Grundfos does not require any specific maintenance. DK - 8850 Bjerringbro, Denmark 14 13 12 Fig.
  • Page 11: Fault Finding The Product

    8. Fault finding the product DANGER Electric shock Death or serious personal injury - Switch off the power supply before you start any work on the product. Make sure that the power supply cannot be accidentally switched on. See also the quick guide. Fault Cause Remedy...
  • Page 12 Fault Cause Remedy The pump runs but The outlet valve is closed. Open the valve. gives no water. No water or too low water level in Increase the installation depth of the the tank. pump. Reduce the pump performance, or replace the pump by a pump with a lower performance.
  • Page 13: Technical Data

    9. Technical data 9.1.5 Frequency of starts and stops 9.1 Operating conditions Maximum starts per hour 9.1.1 Flow rate Maximum flow rate SB HF 9.2 Mechanical data SB HF Cable length Minimum flow rate [l/min] SBA 3-35 SB HF 20/30 SBA 3-45 9.1.2 Maximum head Maximum installation depth...
  • Page 14: Electrical Data

    9.3 Electrical data 9.4 Dimensions Voltage Frequency NPT / G 3/4 [Hz] [kW] [hp] NPT / G 1 3-25 0.57 0.52 3-35 1 x 230 0.80 0.72 3-45 1.05 0.83 3-25 0.70 0.50 3-35 1 x 115 0.90 0.75 3-45 1.10 1.00 3-25...
  • Page 15: Disposing Of The Product

    1. Use the public or private waste collection service. 2. If this is not possible, contact the nearest Grundfos company or service workshop. The crossed-out wheelie bin symbol on a product means that it must be disposed of separately from household waste.
  • Page 16 Appendix SB pump Fig. 1 SB pump...
  • Page 17 SBA pump Fig. 2 SBA pump...
  • Page 18 SB HF pump 182a 182b 182c 105a 176a 154a 157a 156a 155a 193a Fig. 3 SB HF pump...
  • Page 20 China Hong Kong Argentina GRUNDFOS Pumps (Shanghai) Co. Ltd. GRUNDFOS Pumps (Hong Kong) Ltd. Bombas GRUNDFOS de Argentina S.A. 10F The Hub, No. 33 Suhong Road Unit 1, Ground floor Ruta Panamericana km. 37.500 Centro Minhang District Siu Wai Industrial Centre...
  • Page 21 Malaysia Serbia Turkey GRUNDFOS Pumps Sdn. Bhd. Grundfos Srbija d.o.o. GRUNDFOS POMPA San. ve Tic. Ltd. 7 Jalan Peguam U1/25 Omladinskih brigada 90b Sti. Glenmarie Industrial Park 11070 Novi Beograd Gebze Organize Sanayi Bölgesi 40150 Shah Alam Phone: +381 11 2258 740...
  • Page 22 99057358 0618 ECM: 1227326 www.grundfos.com...

Table of Contents