13-108. VENT BLOWER POWER CIRCUIT CHECK. (Refer to Figure 13-26.) With the
HEATER SWITCH in the FAN position, electrical continuity (1 4-28-volts nominal) should
be present at the following locations:
a. Terminal No. 6 on the heater terminal strip.
b. From terminal No. 6 of the heater terminal strip through the radio noise filter to the
ventilating air motor.
c. Electrical ground circuit for the ventilating air motor is provided from terminal No.
4 of the heater terminal strip through the LANDING GEAR SWITCH when the landing gear
is down. Ventilating air motor is inoperative when the landing gear is up.