  • Page 1 PLATINUM FILTER -TASTE AND ODOR (TO) - NEUTRALIZER (NU) - MULTIMEDIA (MM) - BIRM (BM) - NEXSAND MANUAL Professional Installation Version V1.0F 54565...
  • Page 2 NSF/ANSI Standard 44 for material and structural integrity requirements. COMPONENT BRITA ® 828.449.2536 420 3rd Avenue NW www.britapro.com Hickory, NC 28601 BRITA®PRO trademark and logo are registered trademarks of Brita LP and are used under license by Protect Plus, LLC. All rights reserved...
  • Page 3: Table Of Contents

    READ THIS PAGE FIRST BEFORE STARTING INSTALLATION BASICS HOW YOUR FILTER WORKS COMPONENTS & SPECIFICATIONS SPECIFICATIONS INSTALLATION UNPACK & INSTALL CHECK VALVE SERIAL NUMBER & VALVE TYPE PRE-INSTALLATION INSTRUCTIONS ELECTRICAL GROUNDING TOOLS REQUIRED FOR INSTALLATION DETERMINING LOCATION CHECK WATER PRESSURE AND PUMPING RATE FILTER INSTALLATION MEDIA INSTALLATION OPERATION...
  • Page 4: Read This

    See page 8 for unpack and inspect system Do not use this water softener on hot water supplies. Do not install this unit where it may be exposed to wet BRITA PRO reserves the right to change the specifications ®...
  • Page 5: How Your Filter Works

    Correct application is directly associated with the performance and life expectancy of any water filter. It is important, therefore, to understand how your Brita ® NU FILTER* Water Filter functions and to know its capabilities and Automatic Water Filter with Neutralizing Media will limitations so that a correct application can be made.
  • Page 6: Components & Specifications

    COMPONENTS & SPECIFICATIONS TASTE & ODOR (COCONUT SHELL CARBON) FILTERS Flow Rate USGPM Media Cu Mineral Pipe Size Ship Weight Working Temperature = 34-110°F Platinum Series Service Peak Backwash Tank Size Inches (1-43°C) BPF89CB75TO 0.75 8 x 44 3/4” - 1” BPF89CB100TO 1.00 9 x 48...
  • Page 7 WATER AND TIME CONSUMED DURING REGENERATION Models Backwash Rapid Rinse Total Total Water Total Water Consumed Total Water Consumed Minutes Minutes Time of Consumed during during Regeneration during Regeneration Regeneration Regeneration (GAL) (GAL) (MM) (GAL) (Nexsand) (Birm, TO, Neu) SYSTEM DIMENSIONS Step1 Step 2 Models...
  • Page 8: Installation

    INSTALLATION UNPACK & INSPECT PLATINUM FILTER PLATINUM FILTER CONTENTS: • Check the entire unit for any shipping damage or lost parts. FOR MODELS 75,100,150, TO-200, BIRM-200, • Note any damage to the shipping cartons. • Contact the transportation company for all damage and loss claims. YOU WILL EXPECT THE FOLLOWING.
  • Page 9 FOR MODELS 200, 300 PLATINUM FILTER CONTENTS : THE MEDIA AND 200, 300 CONTROL VALVE 1. Tank IS PACKAGED (Model 30 will get an Adaptor and O-ring attached to the tank) SEPARATELY IN 2. Control Valve with Parts Box CARTON AND BAGS 3.
  • Page 10: Check Valve Serial Number & Valve Type

    CHECK THE VALVE SERIAL NUMBER AND VALVE TYPE Check to make sure the valve type matches what you ordered. The serial # label on the left will show BPCVPLATUF for Upflow valve The right Sticker shows the serial # of the control valve. The middle Sticker is dataplate which provides information of Serial # and Date of Manufacture of complete system.
  • Page 11: Pre-Installation Instructions

    PRE-INSTALLATION INSTRUCTIONS CHECK YOUR WATER HARDNESS Use test strips (Part # 2793828-20) to get an estimation of water hardness. Contact your local BRITA PRO dealer to use a ® BRITA PRO laboratory for a complete water analysis free of cost and no obligation to you.
  • Page 12 FIGURE 1B: BIRM (BM) TYPICAL INSTALLATION: Cold Soft Water Hard Filtered Electrical Panel Water Hard Soft Water Ground Strap Raw Water To Outdoors Drain Drain Water Meter Softener Birm Water Heater (BM) Filter FIGURE 1C: MULTI MEDIA FILTER (MM OR NEXSAND) TYPICAL INSTALLATION: Hard Cold Soft Water Filtered...
  • Page 13 FIGURE 1D: NEUTRALIZING FILTER (NF) TYPICAL INSTALLATION: Hard Cold Soft Water Filtered Water Electrical Panel Hard Soft Water Ground Strap Raw Water To Outdoors Drain Drain Water Meter Multi Media Multi Media Taste and Odor Softener Water Heater Filter (MM or neXtSand) Filter (NU) (TO) Filter...
  • Page 14: Tools Required For Installation

    TOOLS REQUIRED FOR CHECK WATER PRESSURE AND INSTALLATION: PUMPING RATE Two adjustable wrenches Additional tools may be required if modifications to home Two water system conditions must be checked carefully plumbing are required. to avoid unsatisfactory operation or equipment damage: Plastic inlet and outlet fittings are included with the softener.
  • Page 15: Filter Installation

    FILTER INSTALLATION Cold (Raw water) Cold (Raw water) Cold (Filtered water) To Outside Faucet In Out Cold (Soft Water) Filter Hot (Soft Water) Water Heater Water Softener Inlet Outlet Opposite Most Standard Softeners NOTE The valves are labeled inlet and outlet on the vale.
  • Page 16: Media Installation

    MEDIA INSTALLATION 1. MEDIA INSTALLATION (WHEN NECESSARY). Models 250 or 300 media are shipped with separate media in pails or CAUTION boxes. Models lower than 2 CF of media come loaded with media and this step can be skipped for new installation. The unit should be de-pressurized before installing or replacing media...
  • Page 17 Fill tank one quarter full of water MULTI MEDIA NEUTRALIZING to protect distribution during gravel FILTER (MMF) installation. FILTER (NF) MEDIA BED MEDIA BED Place the media into the tank in the order indicated above. Slowly and Anthrafilt / carefully add the gravel support bed Anthracite and the filtration media leveling each Calcium...
  • Page 18 Dome Hole Cap Dome Hole Cap Removed The filter is now charged with media. CAUTION Make sure the O-Ring is free of NOTE defects. Use silicone based lubrication (part # 92360) if necessary. DO NOT use petroleum based lubricants as they CAUTION will cause swelling of O-ring seals.
  • Page 19 3. MEDIA INSTALLATION (CARBON UNITS – MODEL TO) Outside faucets used to water lawns and gardens should not Open the inlet on the bypass valve slightly and very slowly allow supply untreated water. A new water line is often required water to enter the unit.
  • Page 20: Operation

    OPERATION STARTUP PROCEDURES 1. CONNECT THE TRANSFORMER TO THE VALVE. 3. SCREEN DISPLAY When power is supplied to the System initializing Plug the 12-volt transformer into a 120 VAC 60 Hz outlet. Please wait control, the screen will display MENU “INITIALIZING WAIT PLEASE”...
  • Page 21: Diagnostic Checklist

    Should there be any questions concerning the advisability of performing a procedure, it is strongly recommended your local BRITA PRO dealer be NOTE ®...
  • Page 22: Softener-Water Bypass-Operating Conditions

    SOFTENER SERVICE Disconnect brine draw line from the brine cabinet. Place the loose end into a five gallon plastic pail filled with a solution of warm water and 4 oz. of resin mineral cleaner. Manually advance control timer to brine draw position (refer to page 16 step 4 chart).
  • Page 23: Maintenance Instructions

    MAINTENANCE INSTRUCTIONS Your chem free iron filter requires some minor maintenance to ensure optimum performance and years of trouble-free clean water. The following steps should be performed once or twice a year (more often under harsh conditions): 1. Verify the pumping rate of the system - do not refer to a pumping curve for this data.
  • Page 24: Backwashing Instructions

    BACKWASHING TO CALCULATE BACK- INSTRUCTIONS WASH FREQUENCY - SPECIAL APPLICATIONS TO CALCULATE BACKWASH FREQUENCY - NORMAL APPLICATIONS To ensure adequate reserve capacity and prevent loss of water pressure between backwashes the figure of 15,000 (not Backwash frequency for households with average water the full 30,000 ppm capacity) is used to calculate backwash use can be determined using the following guide.
  • Page 25: Programming

    PROGRAMMING MASTER PROGRAMMING BELOW IS HOW THE SETTINGS ARE SET AT FACTORY: PRESS MENU KEY AND SCROLL TO PRESS ‘+’ AND ‘-’ FOR 8 SECONDS ‘MAIN MENU’. THEN VALVE SETTINGS PRESS ‘SET’ TILL IT BEEPS MODELS LANGUAGE REGION VALVE METER SALT VS AUTO REGEN.
  • Page 26 STEP A - REGION SETTING Press + and —. Hold until you hear a beep (8 seconds). Press + or — to choose menu option. Press SETTINGS to enter. Press + or — to change option. Press SETTINGS to accept. STANDBY INTERFACE = = Initial Setup interface = = = = Initial Setup interface = =...
  • Page 27: Diagnostic Screen

    DIAGNOSTIC SCREEN PRESS “MENU” KEY AND SCROLL TO “MAIN MENU”. THEN PRESS “SET” TILL IT BEEPS. SCROLL TO ADVANCED MENU Press - to advance to History Values Press “Menu” key . Press - to advance to Main Menu Press“SET” or until you hear a beep. Press “SET”...
  • Page 28: Replacement

    REPLACEMENT REPLACE PISTON AND/OR BRINE VALVE ASSEMBLY Piston Remove 4 X Assembly Seal and Screws Spacer Plate Brine Valve Assembly Follow steps 1 to 6 of Remove the plate from the valve body and Replace piston assembly followed pull the Piston Assembly from the valve. timer /Powerhead replacement.
  • Page 29: Replace Timer

    REPLACE TIMER Meter Cable 4 X Screws Front Cover Disconnect the meter cable from the Remove four screws from the back of Remove the front cover of the valve. the valve cover meter. (If flow meter is attached) Powerhead Piston Screw 2 X Screws from Powerhead Washer Assembly...
  • Page 30: Replace Meter Assembly

    REPLACE METER ASSEMBLY Meter Cable 2X Clips Coupling Adaptor Disconnect the meter cable from the meter. Disconnect the valve from bypass by removing clips Remove the coupling adaptor from the valve Remove the meter support and then the impeller out from the coupling and clean it Replace meter with the help of special tool and re-assemble the removed components back in the section...
  • Page 31: Display Replacement

    DISPLAY REPLACE REPLACEMENT MICROSWITCHES Front Cover 4X Screws Microswitches 2X Screws Remove Screws from the back of the valve and pull the cover Remove all connections from the circuit board Remove the two screws from the microswitch Replace the microswitch, connections and cover AFTER SERVICING Reconnect drain line Return bypass or inlet valve to normal in service...
  • Page 32: Drain Line Flow Control

    REPLACE BRINE LINE REPLACE DRAIN FLOW CONTROL LINE FLOW CONTROL Clip Brine Line Elbow Clip Drain Line Elbow Drain Line Washer Brine Line Washer Pull the drain line clip and remove the Pull the brine line clip and remove drain line elbow and washer the brine line elbow and washer Clean/replace drain line washer Clean/replace brine line washer...
  • Page 33: Filter

    PARTS PLATINUM FILTER PARTS LIST Upper Cone (18280) Bypass 60010004 SYSTEM MINERAL TANK # TANK # TANK # DISTRIBUTOR # VALVE # MEDIA MODEL TANK SIZE (BLACK (BLUE BED # COLOR) COLOR) TP-75 8 x 44 25010025 25010027 25010026 50010005 10010043 95401 TO-100...
  • Page 34: Parts

    CONTROLLER ASSEMBLY PARTS LIST PART # PART DESCRIPTION Micro Switch Cable 60010115 Meter Cable 60010124 Power Cable 60095092 Meter Cable Clip 60095091 Power Cable Clip 92393 Motor 12VAC 3W 60010574 Screw on Mounting Plate 60010573 Mounting Plate 60010660 Motor Pin 60010099 Screw on Main Gear 60010100...
  • Page 35: Standard Bypass Assembly Parts List

    STANDARD BYPASS ASSEMBLY PARTS LIST PART # PART DESCRIPTION WATER GROUP O-ring on Shaft Top Platinum Bypass Shaft Seal 60095614 O-ring on Shaft Bottom 60010069 Secure Clip of Plug 92387 Secure Clip Inlet and Oulet Steel Retainer Ring 60010252 Elbow 1“ NPT Inlet and Oulet 60010592 Straight 1“...
  • Page 36: Standard Valve Body Assembly Parts List

    STANDARD VALVE BODY ASSEMBLY PARTS LIST PART # PART DESCRIPTION 60010184 Brine Line Elbow Nut 60010172 Brine Line Elbow 60010044 O-ring of Brine Line Elbow 60010188 O-ring of BLFC Holder 60010173 BLFC Holder 60010128 BLFC(0.2GPM)(Optional) Brine Line Connector O-ring of Brine Line Connector 60010099 Screw on Valve Bottom Connector 60010599...
  • Page 37 DLFC PART # FOR PLATINUM VALVE PART # PART DESCRIPTION 60095720 BNT95DLFC-0(4.0 GPM) 60010143 BNT95DLFC-1(7.0GPM) 60010144 BNT95DLFC-2(11.0GPM) 60010145 BNT95DLFC-3(14.0GPM) 60010146 BNT95DLFC-4(17.0GPM) 60010147 BNT95DLFC-5(21.0GPM) 60095692 BNT95DLFC-6(24.0GPM) 60095721 BNT95DLFC-1S(2.4GPM) 60095722 BNT95DLFC-2S(3.5GPM) 60095723 BNT95DLFC-3S(4.5GPM) 60010140 BNT95DLFC-4S(5.0GPM) 60095724 BNT95DLFC-5S(6.0GPM) 60095725 BNT95DLFC-6S(6.0GPM) 60010142 BNT95DLFC-7S(7.0GPM) BLFC PART # FOR PLATINUM VALVE PART # PART DESCRIPTION 60010128...
  • Page 38: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE PROBLEM CAUSE CORRECTION 1. FILTER BLEEDS TASTE A. Bypass valve is open A. Close bypass valve AND ODOR OR SEDIMENT B. Electrical service to unit has B. Assure permanent electrical service (check fuse, plug or been interrupted switch) C.
  • Page 39 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 40 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 41: Performance Data Statement

    PERFORMANCE DATA STATEMENT This filtration system has been tested and certified according to NSF/ANSI Standard 42 by IAPMO for the reduction of the substances listed below, as verified and substantiated by test data. The concentration of the indicated substances in the water entering the system was reduced to a concentration less than or equal to the permissible limit for the water leaving the system, as specified in NSF/ANSI Standard 42.
  • Page 42 PERFORMANCE DATA STATEMENT This filtration system has been tested and certified according to NSF/ANSI Standard 42 by IAPMO for the reduction of the substances listed below, as verified and substantiated by test data. The concentration of the indicated substances in the water entering the system was reduced to a concentration less than or equal to the permissible limit for the water leaving the system, as specified in NSF/ANSI Standard 42.
  • Page 43 PERFORMANCE DATA STATEMENT This filtration system has been tested and certified according to NSF/ANSI Standard 42 by IAPMO for the reduction of the substances listed below, as verified and substantiated by test data. The concentration of the indicated substances in the water entering the system was reduced to a concentration less than or equal to the permissible limit for the water leaving the system, as specified in NSF/ANSI Standard 42.
  • Page 44 PERFORMANCE DATA STATEMENT This filtration system has been tested and certified according to NSF/ANSI Standard 42 by IAPMO for the reduction of the substances listed below, as verified and substantiated by test data. The concentration of the indicated substances in the water entering the system was reduced to a concentration less than or equal to the permissible limit for the water leaving the system, as specified in NSF/ANSI Standard 42.
  • Page 45 PERFORMANCE DATA STATEMENT This filtration system has been tested and certified according to NSF/ANSI Standard 42 by IAPMO for the reduction of the substances listed below, as verified and substantiated by test data. The concentration of the indicated substances in the water entering the system was reduced to a concentration less than or equal to the permissible limit for the water leaving the system, as specified in NSF/ANSI Standard 42.
  • Page 46 PERFORMANCE DATA STATEMENT This filtration system has been tested and certified according to NSF/ANSI Standard 42 by IAPMO for the reduction of the substances listed below, as verified and substantiated by test data. The concentration of the indicated substances in the water entering the system was reduced to a concentration less than or equal to the permissible limit for the water leaving the system, as specified in NSF/ANSI Standard 42.
  • Page 47: Warranty

    This limited warranty is solely provided to approved dealers of Brita® Pro Products sold by Protect Plus Pro, LLC and is not applicable to consumers or homeowners. Consumers and homeowners should contact the dealer they purchased their product for warranty information.
  • Page 48 3) LIMITED TEN YEAR WARRANTY FOR MINERAL TANKS AND BRINE TANKS (SILVER SYSTEM AND NRV): Protect Plus Pro, LLC will provide a replacement mineral tank or brine tank to any approved dealer that purchased the new water conditioner assembled unit from Protect Plus Pro, LLC and whose client is in possession of a tank that fails within 120 months, provided that the water conditioner is at all times operated in accordance with specifications, contained within the owner’s manual, and not subject to freezing or...