Sizing - Gardner Denver RNC Series Instruction Manual

Refrigerated type compressed air dryers
Hide thumbs Also See for RNC Series:
Table of Contents

Advertisement

SIZING

Determining dryer capacity at actual operating conditions
To determine the maximum inlet flow capacity of a dryer
at various operating conditions, multiply the rated capacity
from Table 1 by the multipliers shown in Table 2.
Example: How many scfm can an air-cooled model RNC750
handle when compressed air to be dried is at 200 psig and
100°F; ambient air temperature is 80°F?
Answer: 750 x 1.22 x 1.12 = 1,025 scfm.
TABlE 1
Rated capacity (scfm) and pressure drop @ 100 psig inlet
pressure, 100°F inlet temperature, and 100°F ambient
temperature
RNC MODEL
Rated capacity
60 Hz
of air-cooled
50 Hz
models (scfm)
RNC MODEL
Rated capacity
60 Hz
of air-cooled
50 Hz
models (scfm)
10
100
125
150
200
100
125
150
200
84
105
125
170
300
400
500
600
300
400
500
600
250
340
420
540
TABlE 2
Air capacity correction factors (Multipliers)
INLET
PRESSURES
psig
kgf/cm
50
3.5
80
5.6
100
7.0
125
8.8
150
10.5
175
12.3
200
14.0
COOLING MEDIUM*
AMBIENT
250
TEMPERATURE
250
210
°F
°C
80
27
90
32
750
100
38
750
110
43
630
*Air-cooled models; water-cooled models use 1.15 multiplier if cooling water
is below 35°C, 95°F.
INLET COMPRESSED AIR CONDITIONS
INLET TEMPERATURES
80°F
90°F
100°F
27°C
32°C
38°C
2
1.35
1.05
0.84
1.50
1.17
0.95
1.55
1.23
1.00
1.63
1.31
1.07
1.70
1.37
1.13
1.75
1.42
1.18
1.80
1.47
1.22
MULTIPLIER
1.12
1.06
1.00
0.94
110°F
120°F
43°C
49°C
0.69
0.56
0.79
0.66
0.82
0.70
0.91
0.74
0.95
0.80
0.99
0.84
1.03
0.89

Hide quick links: