Enthermics DC250L Operation And Care Manual

120v
Hide thumbs Also See for DC250L:

Advertisement

Quick Links

OPERATION AND CARE MANUAL
: 2 6 2 . 2 5 1 . 8 3 5 6
P H O N E
w w w . e n t h e r m i c s . c o m
.
.
.
p r i n t e d i n u
s
a
DC400L
Corporate Headquarters:
W164 N9221 Water Street
Menomonee Falls, Wisconsin 53052-0443
8 0 0 . T O . B . W A R M
8 6 2 . 9 2 7 6
8 0 0 .
AN ISO 13485:2003 CERTIFIED COMPANY
the warming people®
F L U I D W A R M I N G C A B I N E T
DC250L
(shown with optional
electronic combination
door lock and single
basket insert)
P.O. Box 443
G
.
.
./
U
S
A
CANADA
.
.
./
U
S
A
CANADA
DC250L
DC400L
120V
U.S.A.
G
:
2 6 2 . 2 5 1 . 7 0 6 7
F A X
8 0 0 . 3 2 9 . 8 7 4 4
M N - 3 5 3 0 5 • R e v 2 ( 0 1 / 1 4 )

Advertisement

Table of Contents
loading

Summary of Contents for Enthermics DC250L

  • Page 1 F L U I D W A R M I N G C A B I N E T DC250L DC400L DC250L (shown with optional 120V electronic combination door lock and single basket insert) DC400L OPERATION AND CARE MANUAL...
  • Page 2: Table Of Contents

    T A B L E O F C O N T E N T S Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Troubleshooting Guide .
  • Page 3: Environmental Conditions

    E N V I R O N M E N T A L C O N D I T I O N S Transport and Storage Environmental Operational Environmental Conditions Conditions (not to exceed 15 days) • Unit must acclimate to room temperature •...
  • Page 4: Safety Procedures And Precautions

    SAFETY PROCEDURES A N D P R E C A U T I O N S Knowledge of proper procedures is essential to the safe 1. This fl uid warming cabinet is intended for warming operation of electrically energized equipment. In accordance injection and/or irrigation fl...
  • Page 5: General Information

    Stacking Kits OTHER OPTIONS AVAILABLE CONTACT FACTORY control, is included as an additional safety feature. DC250L over DC250L or DC350 [5013021] • Stackable design - see options and accessories list for available combinations. DC400L C A U T I O N Casters, 3"...
  • Page 6: Dimension Drawings

    4.5" (113mm) D C 2 5 0 L D I M E N S I O N S 9.3" (235mm) CORD LOCATION CORD LENGTH 6' (1.83m) (est.) 24.8" (630mm) 18.4" (470mm) 9.3" (235mm) 15.7" (399mm) CORD LOCATION 3.6" (92mm) CORD LENGTH CORD LOCATION 6' (1.83m) (est.) 12.0"...
  • Page 7: Preparation

    The power specifications are located on the unit identification rating tag. This tag is permanently attached to the unit and must be located to verify power requirements. DC250L POWER REQUIREMENTS DC400L POWER REQUIREMENTS 120 V.A.C. — 60 Hz, 1 ph 120 V.A.C.
  • Page 8: General Warnings

    G E N E R A L W A R N I N G S WARNING The unit requires special precautions regarding EMC A risk of increased emissions or decreased immunity may (Electromagnetic Compatibility) and needs to be installed result if the power cord attached is altered or a manufacturer and put into service according to the EMC information supplied power cable is not used.
  • Page 9 Guidance and manufacturer’s declaration - electromagnetic emissions The unit is intended for use in the electromagnetic environment specifi ed below. The customer or the end user of this unit should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment - guidance Portable and mobile RF communications equipment should be used no...
  • Page 10: Fluid Control Features

    F L U I D C O N T R O L F E A T U R E S Control and LED Display TEMPERATURE MODE IRRIGATION RECALL BUTTON INDICATORS BUTTON BUTTON BUTTON BUTTON LOCKOUT OVER TEMP INJECTION DOWN INTERIOR INDICATOR LIGHT INDICATOR LIGHT BUTTON...
  • Page 11: Optional Fluid Control Features

    O P T I O N A L E L E C T R O N I C D O O R L O C K PROGRAMMING COMBINATION CODE INTO LOCK Optional Lock Control 1 . Select a unique four (4) digit combination code to be used .
  • Page 12: Operational Procedures

    O P E R A T I O N A L P R O C E D U R E S W A R N I N G 1. The appliance should be plugged into an appropriate hospital grade receptacle as specifi ed on the electrical REFER TO FLUID MANUFACTURER’S information page .
  • Page 13: Cleaning And Preventative Maintenance

    C L E A N I N G A N D P R E V E N T I V E M A I N T E N A N C E PROTECTING STAINLESS STEEL, EPOXY COATED AND CLEANING AGENTS PLASTIC SURFACES Use non-abrasive cleaning products designed for use on It is important to guard against...
  • Page 14: Clean The Unit Regularly

    C A R E A N D C L E A N I N G The cleanliness and appearance of this equipment will contribute considerably to its operating efficiency. Make certain the cabinet and door gasket are kept free of any debris that may accumulate. Good equipment that is kept clean works better and lasts longer.
  • Page 15: Troubleshooting Guide

    P531 Pad sensor 5 • Call Service if error persists . - Fluid Warmers: DC250L & DC400L = 3 pads P631 Pad sensor 6 - Blanket Warmers: DC150 & DC250 = 3 pads, DC350 & DC400 = 4 pads, DC750 = 7 pads...
  • Page 16: Zone Heating Pad Locations

    (# = number of pads selected [3-7]) . Press UP or DOWN arrow to adjust to correct number of pads . - Fluid Warmers: DC250L & DC400L = 3 pads - Blanket Warmers: DC150 & DC250 = 3 pads, DC350 & DC400 = 4 pads, DC750 = 7 pads...
  • Page 17: Parts Lists And Drawings

    S E R V I C E FULL ASSEMBLY (DC250L S H O W N PLUG FOR REFERENCE ONLY BASKET ASSEMBLY OPTIONAL DOOR WITH LOCK PART NUMBERS AND DRAWINGS ARE SUBJECT TO CHANGE WITHOUT NOTICE. M N-353 05 • Re v 2 ( 0 1/1 4 ) • DC Fluid Warm er • 15...
  • Page 18 S E R V I C E FULL ASSEMBLY DESCRIPTION DC250L DC400L 1. PANEL, DOOR CV-35300 CV-35301 2. DOOR ASSEMBLY, 5015297 5015298 includes panel standard 3. DOOR ASSEMBLY, WITH MANUAL LOCK 5016415 5015875 optional LOCK ASSEMBLY, WITH KEY LK-35652 LK-35652...
  • Page 19 S E R V I C E FAN ASSEMBLY (DC250L sh o wn DESCRIPTION DC250L DC400L FAN ASSEMBLY, SERVICE KIT ( & includes cliPs baffle riVets screws tHerMostat 5016044 5017337 120V 230V 5016045 5017338 1. CHASSIS PANEL CLIP CL-35031 CL-35031 2.
  • Page 20 S E R V I C E INTERFACE ASSEMBLY (24" w it h eL eCt ron iC L oCk opt ion sh ow n DESCRIPTION DC250L DC400L SCREWS (M4 SC-29333 SC-29333 12mm Plastic tHread cutter WASHER, FLAT WS-22323 SC-29333 WASHER, RUBBER, FLAT...
  • Page 21 S E R V I C E INTERIOR (DC250L sh o wn DESCRIPTION DC250L DC400L 1. DOOR SWITCH SW-35416 SW-35416 2. TOP AIRFLOW INSERT IS-29880 IS-29881 3. CAVITY SENSOR PR-35492 PR-35492 4. SENSOR BLOCK BK-29882 BK-29882 5. SCREW (M4 SC-22271...
  • Page 22: Wire Diagram

    Co mbi n ati on L oCk s how n latch pivot assembly Z O N E H E A T I N G P A D L O C A T I O N S DC250L, DC400L heated pad location ZONE...
  • Page 23: Refer To Wire Diagram Included With The Unit For The

    Refer to wire diagram included with the unit for the correct version. MN-3 5305 • Rev 2 ( 01 /14 ) • DC Fluid Warm er • 21...
  • Page 24: Transportation Damage And Claims

    This warranty 8. Promptly fi le a written claim with the carrier and attach copies of is in lieu of all other warranties expressed or implied and Enthermics all supporting paperwork. Medical Systems neither assumes or authorizes any persons to assume for it any other obligation or liability in connection with Enthermics Medical Systems equipment.

This manual is also suitable for:

Dc400l