  • Page 1 Owner’s Manual ivNow ® 120V/220V/230V Enthermics Medical Systems An ISO 13485:2003 certified company W164 N9221 Water St | Menomonee Falls WI 53051 Tel 262-251-8356 | 800-TO-B-WARM generalinfo@enthermics.com www.enthermics.com Printed in the U.S.A. Specifications are subject to change without notice. Made in the U.S.A.
  • Page 2: Table Of Contents

    E nthe rm ics Me dic a l Syste ms - T h e Warm i ng C o mp any • w w w.e nt h e rm i cs.co m ® MN-38645 • Rev 1 • 04/18 • ivNow Fluid Warmer...
  • Page 3: Delivery

    Serial number: ______________________________________________ information packed with the appliance . Purchased from: ______________________________________________ Indicates that the package contents should Date installed: ______________________________________________ not be used if the package has been damaged or opened. MN-38645 • Rev 1 • 04/18 • ivNow Fluid Warmer...
  • Page 4: Transportation And Damage Claims

    . Additional manuals are available from the Enthermics service department . 3 . Remove all protective plastic fi lm, packaging materials, and accessories from the appliance before connecting electrical power . MN-38645 • Rev 1 • 04/18 • ivNow Fluid Warmer...
  • Page 5: Safety Procedures

    NOTICE: For appliances delivered for use in any location regulated by the following directive ( 2012/19/EU -WEEE) Do not dispose of electrical or electronic appliances with other municipal waste. MN-38645 • Rev 1 • 04/18 • ivNow Fluid Warmer...
  • Page 6: Installation

    Installation How to Install/Mount the ivNow ivNow modular units can be installed in a variety of ways . Up to 3 units can be linked together with a jumper cord and connected via a mounting plate . Configurations can be placed on counter top, mounted to wall or pole .
  • Page 7: Dimensions

    Installation Mounting Instructions •  Mount the rear plate to the wall using 1/4" toggle bolts and washers. Note: For drywall mounFng, drywall must be a minimum thickness of 1/2" •  Remove the two (2) thumb screws from the sides of the rear bracket and set aside. •  Li: the top bracket off of the assembly and set aside. •  Remove the rear bracket from the assembly. •  Use the panel as a template for the hole locaFons Ensure toggle anchors are fully Fghtened MN-38645 • Rev 1 • 04/18 • ivNow Fluid Warmer...
  • Page 8: Electrical Connection

    The power specifi cations are located on the unit identifi cation nameplate . This nameplate is permanently attached to the unit and must be located to verify power requirements . MN-38645 • Rev 1 • 04/18 • ivNow Fluid Warmer...
  • Page 9: Operation

    General Information Safety Feature The ivNow fluid warmer quickly warms and maintains • The control of the ivNow is designed to display an error the temperature of injection/intravenous solutions prior message (E-31) and stop heating if the temperature of to their use . The specially contoured warming module the fluid bag (as monitored by the dual sensor switch) cradles solution bags in 0 .5-, 1-, 2- &...
  • Page 10 5 . The display will continue to show the current bag temperature as the fluid is heated . 6 . The green status indicator will illuminate when the fluid is within +0/-2°C (+0/-3°F) of the setpoint temperature . MN-38645 • Rev 1 • 04/18 • ivNow Fluid Warmer...
  • Page 11 Fluid bag heated residence time is in excess of limit Temperature set point The DISPLAY will flash the word “dAtE” . ivNow will Press and hold the POWER button for 40 seconds or monitor the time spent continuously heating a fluid bag until the current set point (default of 40 °C or 104°F) is...
  • Page 12: Cleaning And Preventative Maintenance

    7 . Check that all display LEDs light up . Test by turning the unit off and then on . All LEDs illuminate for one second at start-up . 8 . Contact the Enthermics Service department for immediate repair if any problems exist . WARNING...
  • Page 13: Troubleshooting

    . 3 . If the warmer still displays a temperature, contact service . MN-38645 • Rev 1 • 04/18 • ivNow Fluid Warmer...
  • Page 14 Enthermics Medical Systems An ISO 13485:2003 certified company W164 N9221 Water St | Menomonee Falls WI 53051 Tel 262-251-8356 | 800-TO-B-WARM generalinfo@enthermics.com www.enthermics.com Specifications are subject to change without notice. Made in the U.S.A. Printed in the U.S.A.

Table of Contents