Telycam TLC-300-IP-12 User Manual

Telycam TLC-300-IP-12 User Manual

12x hd ip ptz video camera

Advertisement

12x HD IP PTZ Video Camera
User Manual
Version V1.0
(English)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TLC-300-IP-12 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Telycam TLC-300-IP-12

  • Page 1 12x HD IP PTZ Video Camera User Manual Version V1.0 (English)...
  • Page 2: Table Of Contents

    CONTENT CONTENT ......................................1 SAFETY GUIDES ....................................2 PACKING LIST....................................... 3 QUICK START ....................................... 3 PRODUCT HIGHLIGHTS..................................4 CAMERA SPEC..................................... 4 CAMERA INTERFACE.................................... 6 CAMERA DIMENSION..................................6 IR REMOTE CONTROLLER..................................7 VISCA(RS232)PORT..................................9 VISCA PROTOCOL ....................................10 PELCO-D PROTOCOL ..................................
  • Page 3: Safety Guides

    SAFETY GUIDES 1.Before operation, please fully read and follow all instructions in the manual. For your safety, always keep this manual with the camera. 2.The camera power input range is 100-240VAC(50-60Hz),ensure the power supply input within this rate before powering on. 3.The camera power voltage is 12VDC, rated currency is 2A.
  • Page 4: Packing List

    PACKING LIST Check all bellow items when open the package: Camera · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 1 Power Adapter ·...
  • Page 5: Product Highlights

    PRODUCT HIGHLIGHTS  Adopts most advanced ISP, 1/2.8 inch 5MP sensor, providing full HD video resolution and crystal clear image.  High end 12x optical zoom, 2x digital zoom lens with 72.5 degree field of view.  IP, HDMI, 3G-SDI, USB video outputs interface, fit for different application ...
  • Page 6 Zoom F3.92~47.32mm(12X),, View Angle:72.5°(Far)-6.43°(Near) Rotation Angle Pan: -170° ~ +170°; Tilt: -30° ~ +90° Rotation Speed Pan: 0°~120° /s ; Tilt: 0°~80° /s Preset: Remote controller: 10; RS232: 128; Accuracy: 0.1° Control Port RS232、RS485(optional)、RJ45 (VISCA over IP)、USB3.0(UVC1.5) Network Speed 1000M Video encode H.264/H.265(default: H.264) Bit Rate Control...
  • Page 7: Camera Interface

    CAMERA INTERFACE 1.Camera Lens 6. Tripod Screw Hole 10. HDMI port 2.Camera Base 7. Installation Hole 11.3G-SDI port 3.IR Receiver Panel 8. RS232 control port (input) 12, USB port 4.Power Indicator Light 9. RS232 control port(output) 13, RJ45 port 5.Dial Switch 14.
  • Page 8: Ir Remote Controller

    IR REMOTE CONTROLLER POWER Under normal working mode, short press POWER key, to enter standby mode; Press it again, the camera will do self-configuration, then go back to HOME position. It will go to preset position if power on model has been set before. FREEZE (Not Supported in USB)...
  • Page 9 FOCUS KEY ( ON THE LEFT) Manual focus, only valid under manual focus model. ZOOM KEY( ON THE RIGHT SIDE) Set the zoom rate NAVIGATE KEY: UP/DOWN/LEFT/RIGHT Under working mode, use navigate key to set the pan tilt, and select menu when enter OSD.
  • Page 10: Visca(Rs232)Port

    VISCA IN (RS232 PORT) V_IN V_OUT VISCA IN RS485 A(+) IR OUT IR OUT B(-) VISCA IN &Mini DIN Connection VISCA IN & DB9 Connection Camera VISCA IN Camera VISCA IN Windows DB-9 Mini DIN A(+) A(+) IR OUT IR OUT B(-) B(-) VISCA Network Construction:...
  • Page 11: Visca Protocol

    VISCA PROTOCOL Part1 Camera Return Command Ack/Completion Message Command Packet Note z0 41 FF Returned when the command is accepted. Completion z0 51 FF Returned when the command has been executed. z = camera adderss+8 Error Messages Command Packet Note Returned when the command format is different or when a command with illegal command Syntax Error z0 60 02 FF...
  • Page 12 Command type function command Stop 8x 01 04 08 00 FF Far(Standard) 8x 01 04 08 02 FF Near(Standard) 8x 01 04 08 03 FF Far (Variable) 81 01 04 08 2p FF p=0 (Low) to 7 (High) Near (Variable) 81 01 04 08 3p FF p=0 (Low) to 7 (High) CAM_Focus...
  • Page 13 Command type function command Bright 81 01 04 39 0D FF Bright Mode (Manual control) Reset 8x 01 04 0A 00 FF 8x 01 04 0A 02 FF Shutter Setting CAM_Shutter Down 8x 01 04 0A 03 FF Direct 8x 01 04 4A 00 00 0p 0q FF pq: Shutter Position (0~0x15) Reset...
  • Page 14 Command type function command 8x 01 06 A5 02 FF CAM_RS485Ctl 8x 01 06 A5 03 FF CAM_Saturation Saturation 8x 01 04 A1 00 00 0p 0q FF pq :saturation level 0x00~0xff CAM_Contrast Contrast 8x 01 04 A2 00 00 0p 0q FF pq :Contrast level 0x00~0xff 8x 01 06 A0 02 FF...
  • Page 15 Command type function command 0y FF Menu On 8x 01 06 06 02 FF Turn on the menu Menu Off 8x 01 06 06 03 FF Turn off the menu SYS_Menu Menu Back 8x 01 06 06 10 FF Menu step back Menu Ok 8x 01 7E 01 02 00 01 FF Menu ok...
  • Page 16 50 pp FF CAM_IDInq y0 50 ab cd CAM_VersionInq 8x 09 00 02 FF mn pq rs tu vw FF VideoSystemInq(Telycam) 8x 09 06 23 FF y0 50 pp FF pp: Video format VideoSystemInq(Sony) 8x 09 04 24 72 FF...
  • Page 17 pqrs : Column(x size) MainstreamResolutionInq 8x 09 04 C2 00 FF y0 50 0p 0q 0r 0s 0m 0n 0x 0y FF mnxy: Line (y size) only support:1920*1080,3840*2160 MainstreamRateInq 8x 09 04 C2 01 FF y0 50 0p 0q 0r 0s 0m 0n 0x 0y FF pqrsmnxy: bitrate (0~15360) pqrs : Column(x size) SubstreamResolutionInq...
  • Page 18: Pelco-D Protocol

    PELCO-D Protocol Command List Function Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 0xFF Address 0x00 0x08 Pan Speed Tilt Speed Down 0xFF Address 0x00 0x10 Pan Speed Tilt Speed Left 0xFF Address 0x00 0x04 Pan Speed Tilt Speed Right 0xFF Address 0x00 0x02...
  • Page 19: Pelco-P Protocol

    PELCO-P Protocol Command List Function Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Byte8 0Xa0 Address 0x00 0x08 Pan Speed Tilt Speed 0Xaf Down 0Xa0 Address 0x00 0x10 Pan Speed Tilt Speed 0Xaf Left 0Xa0 Address 0x00 0x04 Pan Speed Tilt Speed 0Xaf Right 0Xa0...
  • Page 20: Osd Menu

    OSD MENU 1. Under working mode, press the MENU key on the IR remote controller, to enter the OSD menu as bellow: 2, After enter the main menu, use the navigate UP/DOWN key to select the main menu. Once been selected, the main menu will change to blue background, and the right side will show all sub menu options.
  • Page 21 Optional: AUTO,INDOOR,OUTDOOR,MANUAL,OUTAUTO,SODIUM WB MODE Default:ATW LAMP AUTO ,SODIUM LAMP R GAIN Red gain level: 0~255, only valid under manual white balance mode. Default:AUTO IMAGE B GAIN Blue gain level:0~255 , only valid under manual white balance mode Default:AUTO DEFOG OFF, 1~15 Default:OFF RETURN Return to previous menu...
  • Page 22: Uvc Control

    CAM RESET Reset camera parameter to default RESET PTZ RESET Reset pan/tilt parameter to default ALL RESET Reset all parameter to default RETURN Return to the previous menu CONTROL VER Camera control firmware version CONTROL DATE Camera control firmware releasing date FORMAT Current video output format INFO...
  • Page 23: Web Setting

    5.Support standard UVC interface. PU_BRIGHTNESS_CONTROL 81 01 04 4d 00 00 0p 0q FF PU_CONTRAST_CONTROL 81 01 04 A2 00 00 0p 0q FF PU_SATURATION_CONTROL 81 01 04 A1 00 00 0p 0q FF PU_SHARPNESS_CONTROL 8x 01 04 42 00 00 0p 0q FF PU_GAMMA_CONTROL 8x 01 04 5B 0p FF PU_WHITE_BALANCE_TEMPERATURE_CONTROL...
  • Page 24 If you are log in web interface first time, there maybe show up a mistake notice as bellow, the reason is the explorer prevent the web interface to run Flash Player, what we need to do is to enter explorer setting, to set it allow to use Flash Player. Preview interface as above image, on the right side, there are options to control camera pan, tilt, zoom, focus, presets, focus speed, zoom speed can be set.
  • Page 25 “Video Encode”: can set image encode mode, main stream and sub stream resolution/bit rate/frame rate, bit rate control way, and I frame interval etc as above image “Image Parameter”can set focus, exposure, white balance, image, image quality, noise-reduction, as following picture Focus including focus mode, default focal distance, digital zoom etc Exposure includes exposure mode, shutter speed, gain, iris, brightness, and anti-flicker.
  • Page 26 Noise reduction includes 2D/3D reduction. There is on/off option for 2D, and off/auto/1~4 six options. “Ethernet” includes DHCP mode, IP address, subnet mask, default gateway, http port, web port, main stream port, sub stream port. Default parameter as following: DHCP HTTP port IP address 192.168.1.188...
  • Page 27: View Rtsp Video Via Vlc

    Reset to default : reset the camera to default setting Reset simply: reset camera image parameter Reset Completelyall: reset camera Ethernet and image parameter, language and protocol will not be reset. Reboot: Reboot ISP part of camera Account Setting: is used for setting camera account and password Input the account firstly, then input same password twice, click set to finish Please remember account and password, otherwise you may be not able to login.
  • Page 28: Visca Over Ip

    Note: If there is much image lag, select “more option” to enter into following setting, change buffer time smaller (VLC default buffer time is 1000ms). VISCA over IP VISCA over IP means VISCA protocol transmit via IP, to reduce RS232/RS485 cable layout (the controller must support IP communication function) Communication port spec: ...
  • Page 29 Note: LAN output way is big-endian, LSB is in the front. Payload type: Data definition as following: Name Value (Byte 0) Value (Byte 0) Value (Byte 0) VISCA command 0x01 0x00 Stores the VISCA command. VISCA inquiry 0x01 0x10 Stores the VISCA inquiry. Stores the reply for the VISCA command and VISCA VISCA reply 0x01...
  • Page 30 Save VISCA return packet  VISCA device setting command Save VISCA equipment setting command packet.  Control command The following data is saved in control command payload  Controlled reply The following data is saved in return command payload of control command. Delivery confirmation VISCA over IP uses UDP as transmission communication protocol, UDP communication message transmission is not stable, it is necessary to confirm delivery and resent in application.
  • Page 31 Sequence chart as following Sequence chart when returned message lost Sequence chart when command lost Note: Do not set IP address, subnet mask, gateway parameter in VISCA over IP command, otherwise, it will cause network breaks off. Due to change these parameter, network will be in off status.