Fuel Conversion - Lennox Elite Series Installation And Operation Manual

Direct vent
Table of Contents

Advertisement

Fuel Conversion

Converting the stove between natural gas (NG) and propane (LP) can be
accomplished by either changing the cassette (valve and pilot assembly)
or installing a conversion kit (regulator, burner orifice and repositioning
the slide orifice of the pilot). Only a qualified service technician should
perform the conversion.
Conversion Kit
Please see instructions provided with conversion kit.
Cassette Removal
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous
operation.
ATTENTION: Au moment de l'entretien des commandes,
étiquetez tous les fils avant de les débrancher. Des erreurs
de cáblage peuvent entraîner un fonctionnement inadéquat et
dangereux.
1. Be sure the gas supply is shut off. The electrical supply for the blower
should be unplugged from both the wall and the Epic™ gas stove
before beginning the conversion.
2. Disconnect back of pedestal by removing the four button head cap
screws securing it, slide back far enough to label and disconnect wires
from the AC inlet plug. Remove the white remote thermostat plug.
Completely remove back of pedestal from the Epic gas stove.
3. Disconnect the gas supply from the stove, being careful not to apply
pressure to the valve in the process.
4. Remove socket head cap screw securing the bottom of the right side
door, open, label and remove the wires leading to the snap switch.
5. Remove the control panel containing the On/Off switch by removing
the four socket head cap screws securing it. Pull the control panel
out far enough to remove the orang e piezo igniter wire. Detach the
two black wires from the back of the On/Off switch, disconnect the
fan control wires and completely remove the control panel. Remove
the knob extensions from the valve controls.
6. Remove the log set and brick panels (see Brick Panel, Log Set and
Ember Installation).
7. Remove the two screws from the back of the burner. Lift the left end
of the burner and slide if off the orifice and shutter tube. Remove the
burner from the firebox.
8. From inside the firebox, remove the right side burner support. Then
remove the seven socket head cap screws holding the cassette in
place.
9. From inside the pedestal remove the four 3/8" nuts holding the back
of the control panel.
26
10. Mark and unplug the remaining fan wire. Remove the three screws
securing the fan and set aside.
11. Remove the cassette assembly by carefully pulling the top cassette
plate downward, guiding the pilot assembly out of the firebox, down
into the pedestal area. Once the pilot assembly is clear of the firebox,
remove the cassette from the pedestal.
12. Install the new, converted, or serviced cassette in the reverse order of
removal. All surfaces of the cassette must be sealed to the firebox
to ensure an air tight seal. The old gasket must be replaced with a
new gasket.
13. All parts and wires must be correctly reinstalled to ensure safe and
proper operation of the unit.
Figure 36
Figure 37
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Blower Removal
Cassette Screws

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite epic 33Elite epic 40

Table of Contents