MESSAGE NO.
EVENT
1
Alarm
2
Tampering
3
24H Panic
4
24H Technical
5
Pre-alarm
6
Detectors
7
Activated
8
Deactivated
Notice - Configuring the commands to be executed:
"Type" select whether to run a scenario, a group or a single automation
unit. (warning, the alarm system arming/disarming scenario cannot be run).
"Name" in the appearing list, select the name of the scenario, group or
individual automation unit to be run.
"Command", specify the command to be run, if you chose to run a Group
or a single automation unit.
Confirm with "OK" to save and exit. ON: to define the activation start
time for the event notice;
OFF: to define the activation end time for the event notice;
Days: to define the days of the week when the event notice is enabled;
Voice Msg.: to associate a voice message that will be played by the touch
screen at the time of executing the notice.
05. Confirm with "OK" to save and exit.
To edit or delete a notice:
06. Turn on the touch screen keypad, touch the icon
scroll through with
and select
07. Touch the "Notice" you wish to edit or delete;
08. To edit press "Edit" and resume from point 04;
09. To delete, press "Delete", confirm by selecting "YES" and pressing "OK".
DESCRIPTION
GENERAL ALARM: generated by one of the detectors. Generated by a zone A-B-C-D-E-F
TAMPERING ALARM: All tamper-proof devices can trip this alarm.
PANIC ALARM: alarm activated manually by the user via transmitter or keypad.
TECHNICAL ALARM: alarm activated by technical sensors (smoke, flooding, and others).
PRE-ALARM: status where an intrusion was detected but the sensor is set with intervention delay. Time needed by
the user to deactivate the system without activating the sirens.
Detection generated by a specific sensor even with the system is not armed.
Generates a notification when one or more partitions are activated.
Generates a notification when one or more partitions are deactivated.
in the main screen,
to enter the "Notice List" menu;
TABLE 2
4.16 - Event log
This function displays a report of the last 100 commands sent.
01. Turn on the touch screen keypad, touch the icon
scroll down and select the icon
02. Scroll through with the arrows
a
07/12/2011
GATE
d
a - date
b - time
c - command origin: L - Locally from the touch screen / S - SMS / N - Event notice
T - Timer
d - name of the automation unit, scenario, group or timer run
e - name of the command sent
in the main screen,
to view the events.
b
c
07:58:36
L
1 OPEN
e
English – 11