Mounting The Sensor Wheel - Siemens Simodrive SIMAG H Planning/Installation Manual

Measuring system for main spindle drives
Table of Contents

Advertisement

4 Installation/Calibration
4.1

Mounting the sensor wheel

Note
The eccentricity of the installed sensor wheel affects the accuracy of
the whole system (see Section 3).
Do not allow permanent magnets, magnetic mounts for clock gauges, etc. to
come into contact with the sensor wheel!
Tolerances,
Permissible radial eccentricity and axial eccentricity tolerances as well as
motor shaft
position tolerances of the drilled holes, refer to Section 5.1.
Installation
The sensor wheel can be attached to the shaft by the following methods:
methods
1. Shrink fit
2. Axial screw mounting
3. Axial clamping
For information/instructions on this, refer to Table 4-1.
Table 4-1
Mounting types, designation of the diameter, refer to Section 5.1
Application
Diameters D3, D4, D5
Shrink fit
D3/D5
(mounting type)
press fit, e.g. H6 / r6 or H6 / s6
Screw connection
D4
(mounting type)
Material weakening above D4 not
permissible
Shaft nut
–––
(mounting type)
D3 screw on
D–customer
Material weakening above D4 not
permissible
Clearance fit
D3/D5
Max. permissible play: +0.03 mm
4-22
SIMODRIVE sensor, Measuring System for Main Spindle Drives SIMAG H (PMH) – 07.02 Edition
Information
S
Inductive heating is not permissible to inductively
heat–up
S
Max. sensor wheel temperature, 120_ C
S
Mounting holes/withdrawal threads must be provided
by the customer
S
Screws and washers are not included in the scope of
supply
S
Note the tightening torque (refer to Fig. 5-2)
S
The shaft nut is not included in the scope of supply
S
Tightening torque:
M
= f(F
), F
= 20 kN acc. to the manu-
D
clamping
clamping
facturers data
S
Locate over D2 with pliers
S
Maintain the radial eccentricity of 0.02 mm from D3 to
D1
–––
 Siemens AG 1999–2002 All rights reserved
07.02

Advertisement

Table of Contents
loading