7.
Install the drain pump. Carefully slide in, aligning
the tab on the pump base to the rectangular slot
in the unit base. (Fig. 2)
8.
Attach the drain tube from the bin to the pump inlet. Install the vent tube and drain tube to the
household drain before securing the pump to the unit base. The vent tube and drain tube
should be threaded through the component compartment cover. (Fig. 3)
Vent Tube
Drain Tube
(Pump to
Household
Drain)
Fig. 3
9.
Coil the power cord from the Ice Maker into a figure 8. Wrap electrical tape around the center
of the figure 8. Place the wrapped cord between the compressor and the drain pump. Install
the plug on the power cord to the electrical outlet of the drain pump.
10.
Line up the two (2) holes at the rear of the pump with the two holes in the unit base and install
two (2) #8 x ½" hex-head screws. (Fig. 3)
11.
Secure the vent tube to the back of the ice maker
using three (3) clamps and three (3) #8 x ½"
hex-head screws supplied in the drain pump
kit. (Fig. 4)
12.
Check all connections for leaks.
13.
Reinstall the component compartment cover.
14.
Connect the power cord from the drain pump to
the house hold electrical supply in accordance
with National Electrical Code and local codes
and ordinances.
Pump Mounting
Tab
Pump Mounting
Screws
Vent
Tube
Fig. 4
23
Fig. 2
Drain Tube
(Pump to
Household
Drain)
Drain Pump
Vent Tube
Mounting
Clamp &
Screw

Hide quick links: