Clean Cycle
Electrical System
In the electrical system, power is supplied to the water recirculating pump through the service control
switch.
Water System
In the water system, water recirculating pump circulates the cleaning solution that has been added to
the reservoir up to the distributor, across the evaporator, and back into the reservoir where it is recir-
culated while the service control switch is in the "CLEAN" position.
Table 1-2 shows how the electronic control board controls the various components and systems
during the DIAGNOSTIC/CLEAN CYCLE.
CLEAN CYCLE
DIAGNOSTICS
CLEAN CYCLE
47 MINUTES
SECONDS
5
5
5
5
5
WATER VALVE
CONDENSER FAN
HOT GAS VALVE
WATER RECIRC. PUMP
COMPRESSOR
LED
The first 25 seconds of this cycle will operate each one of the electrical components for five (5)
seconds each.
Table 1-2
8