6.1.1.6 INSPECT AND FLUSH DHW STORAGE TANK
The storage tank should be inspected annually and cleaned if required. To gain access for inspection please carry
out the following procedure:
Turn off the electrical supply to the heater
Shut of the cold water supply to the tank
Open a hot water outlet until water fl ow stops
Shut off hot water outlet and return feed to the tank.
Drain off approximately 5 - 10 litres of water from the tank drain point (see illustration below).
Tank drain valve
Remove the insulation material on the top of the tank to reveal the tanks connections.
If necessary, disconnect any pipework connections to allow removal of the Tank Inspection Hatch.
Clamp nut
Loosen nut on Tank Inspection Hatch and unscrew bolt to the end of the thread, but do not remove.
Wrap a length of wire around the threaded shaft underneath the clamp and hold the wire to prevent the hatch
falling into the tank, when the bolt is removed
Tap the hatch, so that the hatch drops downwards and is held in place by the nut.
Remove the bolt and clamp and while holding the threaded shaft allow the hatch to drop down and then angle
the hatch and remove it through the opening.
With the use of a torch it should be possible to see to the very bottom of the inside of the tank. If the tank is clear of
deposits then no further action is necessary and the hatch can be replaced as a reverse of the above procedure.
Take care not to drop the hatch into the tank when replacing it.
If the tank requires fl ushing, allow all the water to fl ow from the tank by opening the drainage tap fully . A hose pipe
connected to the cold water supply, can be inserted into the hatch opening to wash away any remaining deposits
out of the drainage tap. In areas with hard water, it maybe necessary to fl ush out the water heater more frequently.
To refi ll the tank after inspection or fl ushing, perform the following procedure:
Close the drainage tap
Secure the inspection hatch
Turn on the cold water supply to the tank and open the hot water return pipework
Open hot water outlets in turn until all air is expelled
Turn on the power to the heater and activate a hot water demand.
Maintenance