Powering the Access Point
Note
Failure to install the cable gland and rubber gasket properly will cause the cable grip to leak.
Warning
Figure 2-26
1
Washer (Rubber Gasket)
3
Sealing insert
5
Thread-lock sealing nut
Step 5
Insert the unterminated end of the Ethernet cable through the sealing nut end of the cable gland (see
Figure
Install an RJ-45 connector on the unterminated end of the Ethernet cable using your Ethernet cable
Step 6
installation tool.
Warning
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. Statement 1023
Warning
When installing the RJ-45 connector, ensure that cable gland and the rubber gasket are present and
installed properly, to avoid water leakage into the enclosure. See
Step 7
Carefully insert the RJ-45 cable connector into the Ethernet port opening on the access point, and
connect to the internal Ethernet connector (see
Cisco Aironet 1530 Series Outdoor Access Point Hardware Installation Guide
2-44
Verify that the cable gland has a rubber seal and ensure that it is not damaged.
Cable Gland
2-26), and pull several inches of cable through the adapter.
Chapter 2
2
Body
4
Clamping claw
Figure 2-26
Figure
2-27).
Installing the Access Point
and
Figure
2-27.