12.0 SETTING RELAY COMMANDS WHEN USING THE A 6500 WITH THE A 6510/ A 6515

In order to use the relay outputs of the Redback® A6510 or A 6515 when using the CAT5 direct connection from the
A 6500 wall plate (see fig 12.2 and 12.3), specific serial commands have to be sent. These external relays cannot be acti-
vated using the standard relay commands.
Follow the same steps as outlined in section 9.0 to create a new serial command for a button through the Add New Com-
mand window.
There are three options for the state of the external relays, ON, OFF or Toggle.
Specific ASCII codes have to be sent to switch the desired relays.
Figure 12.1 illustrates the settings required to toggle relay 1.
The port must be set to 1, the speed to 9600 baud, the stop bit to 1, data bits to 8 , parity to none and the format must
be ASCII.
(Cat5/6 Cable 50m Maximum)
Redback® A 6500
(Cat5/6 Cable 50m Maximum)
Redback® A 6500
www.altronics.com.au
Fig 12.1
Relay OUT
12
11
10
9
8
7
6
5
4
3
2
1
Fig 12.2
Relay OUT
2
1
Fig 12.3
The code to be sent is quite simple.
The code starts with the word RELAY followed by
T for toggle, O (capital o) for OFF and I (capital i) for
ON, followed by the relay number.
So for instance to turn on relay 5, the code would
be RELAYI5, to toggle relay 12, the code would be
RELAYT12 and so on.
It is also possible to turn all relays ON or OFF by
using the standard format of O (capital o) for OFF, I
(capital i) for ON and then by using the number 99
as the relay number.
so the command RELAYI99 will turn all relays ON
and the command RELAYO99 will turn all relays OFF
24V DC PLUGPACK
(MINIMUM 1A)
Redback® A 6510
RELAY CONTROLLED DEVICES
(CONTACTS MAX 1A)
24V DC PLUGPACK
(MINIMUM 1A)
Redback® A 6515
RELAY CONTROLLED DEVICES
(CONTACTS MAX 16A)
Redback® Proudly Made In Australia 15
NOTE: The A 6510 relays are
numbered 1-12.
NOTE : DIP Switch 3 must be
set to ON in this wiring config-
uration. All other DIP switches
must be OFF.
NOTE: The A 6515 relays are
numbered 13 &14.
NOTE : DIP Switch 3 must be
set to ON in this wiring config-
uration. All other DIP switches
must be OFF.