Harvest Button; Manual Harvest; Unit Check; Clean Button - Cornelius Xtreme ICE Series Owner's/Operator's Manual

Table of Contents

Advertisement

HARVEST BUTTON

Manual Harvest

1. At any time after secondary start up, the machine can be put into the harvest cycle by depressing the har-
vest button.
2. Pressing the harvest button will tell the microprocessor to skip directly to the harvest cycle.
3. Once the harvest cycle completes, the machine continues with normal operations.

Unit Check

1. Like manual harvest, any time after secondary start up the micro processor monitors the harvest button.
2. If the harvest button is depressed and held for 5 seconds, the unit goes into a check mode.
3. All outputs are initially turned off.
4. Then the microprocessor powers each output individually for one second.
5. This continues for 10 minutes or until the power is cycled.

CLEAN BUTTON

CLEAN CYCLE

1. The clean cycle can only be initiated during the 45 second hot gas cycle in Secondary Start Up.
2. The clean cycle starts when the CLEAN button is pressed.
3. The hot gas valve opens.
4. The microprocessor monitors the proximity switch circuits, waiting for all circuits to open.
5. Once all circuits have opened, the hot gas valve closes.
6. If all of the proximity switch circuits do not open in 4 minutes, the hot gas valve closes.
7. The fill valve opens.
8. Once the water level reaches the maximum water level, the fill valve closes.
9. The water pump turns on.
10. After 10 minutes the dump valve opens.
11. Once the water reaches the minimum level, the water pump turns off and the dump valve closes.
12. The fill valve opens.
13. Once the water reaches the maximum water level, the fill valve closes.
14. The water pump turns on, and the dump valve opens.
15. Once the water reaches the minimum water level, the water pump turns off and the dump valve closes.
16. The fill valve opens.
17. Once the water reaches the maximum water level, the fill valve closes.
18. The water pump turns on, and the dump valve opens.
19. Once the water reaches the minimum water level, the water pump turns off and the dump valve closes.
20. All outputs turn off.
21. The ERROR LED flashes 6 times at 4 second intervals.
22. The machine will not run until the power is cycled off and back on.